2. General
2.2
Installation requirements
Environment conditions
Table below summarizes the physical environment in which the Prometheus may be safely operated or stored.
Environment
Operating
Non-Operating
Ambient Temperature
10°C (50°F) to 35°C (95°F)
-15°C (5°F) to 60°C (140°F)
Air cleanliness
Clean of
fi
ce environment (equivalent with cleanroom
standard ISO 14644-1 ISO Class 9)
n.a.
Humidity
5% to 85% RH Non-condensed
5% to 95% RH Non-Condensed
Altitude
-60 (-197Ft) to 3000m (9843Ft)
-60 (-197Ft) to 10000m (32810Ft)
Let the projector acclimatize after unpacking. Neglecting this may result in a startup failure of the Light Pro-
cessor Unit.
Cooling requirements
The projector is fan cooled and must be installed with suf
fi
cient space around the projector head, minimum 20 cm (8 inch) to ensure
suf
fi
cient air
fl
ow. It should be used in an area where the ambient temperature, as measured at the projector air inlet , does not
35°C (+95°F).
The installation of an
exhaust system
is
MANDATORY
. The installed exhaust blower must remove an air volume of minimum
10m
3
/min (350 CFM)
measured at the exhaust output of the projector.
Main Power requirements
Projector
Power requirements
Prometheus I
200-240 VAC, 50-60Hz, 30A at 200 VAC (mono phase)
Prometheus II
230/400V 3W+N+PE 16A 50-60Hz (Y connection) or 208V 3W+PE 27A 50-60Hz (
Δ
connection)
The power cord required to connect the projector with the power net is not delivered with the projector. It is the responsibility of the
customer to provide the correct type of power cord. The cross-sectional area of the conductors in the power supply cord shall not
be less than 4 mm² or 10 AWG, minimum 300V.
To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that the instrument panel
and cabinet be grounded. In no event shall this projector be operated without an adequate cabinet ground connection.
The AC supply must be installed by a quali
fi
ed electrician in conformance to local codes. Hardware, wire sizes and conduit types
must comply with local codes.
A readily accessible disconnect device shall be incorporated externally to the equipment for removal of the power to the equipment
mains terminals.
The building installation must be provided with a circuit breaker of max. 40A to protect the complete unit.
W
ARNING
:
Disconnect the power to the unit mains terminals and unplug power cord at UPS inlet for removal
of all power from the unit
UPS requirements
The Uninterruptible Power Supply (UPS), also known as a Continuous Power Supply (CPS), must have an output voltage of 200-240V
at 50-60Hz and must be capable of delivering an output current of 5,5 amperes. This UPS provides only power for the electronics
and not for the lamp.
The connection between the UPS unit and the UPS inlet of the projector must be done with a certi
fi
ed AC power supply cord of
minimum 0,75 mm² or 18 AWG and minimum 300V.
C
AUTION
:
The 200–240V power outlet (UPS OUTLET) of the projector may not be used to provide the UPS
unit with power! The UPS OUTLET of the projector may only be used for connection to the UPS INLET of the
projector.
The Prometheus does not have a built in UPS unit.
R5905963 PROMETHEUS SERIES 09/03/2015
15
Summary of Contents for Prometheus I
Page 1: ...Prometheus series Installation safety manual R5905963 00 09 03 2015 ...
Page 15: ...1 Safety PR Image 1 2 R5905963 PROMETHEUS SERIES 09 03 2015 11 ...
Page 92: ...5 Lenses lens holder 88 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 124: ...7 ICMP 120 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 130: ...8 Communicator Touch Panel 126 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 134: ...9 Starting up 130 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 152: ...10 Removal and installation of the projector covers 148 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 176: ...13 Specifications 172 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 186: ...14 Pin configurations 182 R5905963 PROMETHEUS SERIES 09 03 2015 ...