4. Lamp & Lamp House
4.12 Realignment of the lamp in its re
fl
ector (manual Lamp House)
Each xenon lamp installation requires a realignment of the lamp in its re
fl
ector for optimal performance of the
xenon lamp in the Prometheus. Furthermore, it is recommended to realign the lamp after the
fi
rst run time of
100 and 200 hours. Especially the Z-axis of the lamp.
How to realign
1. Remove the lamp cover to get access to the X-, Y- and Z-axis adjustment thumbscrews of the lamp.
2. Some lamp houses may have lock nuts on the X and Y adjustment screws which are locked. Before starting the adjustment, fully
turn these lock nuts against the thumbscrew.
Image 4-51
Lock nuts
3. Switch on the projector and start up the lamp.
4. Go via the Communicator touch panel to the menu
“Installation”
>
“Lamp”
>
“Light output”
.
5. Set the “
Light output mode
” in
normal mode
and the “
Lamp Dimming
” on maximum (
255
).
Note:
This window on the Communicator touch panel shows in the upper left corner the measured value of the built-in light
sensor of the projector.
Image 4-52
Light mode selection
R5905963 PROMETHEUS SERIES 09/03/2015
67
Summary of Contents for Prometheus I
Page 1: ...Prometheus series Installation safety manual R5905963 00 09 03 2015 ...
Page 15: ...1 Safety PR Image 1 2 R5905963 PROMETHEUS SERIES 09 03 2015 11 ...
Page 92: ...5 Lenses lens holder 88 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 124: ...7 ICMP 120 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 130: ...8 Communicator Touch Panel 126 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 134: ...9 Starting up 130 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 152: ...10 Removal and installation of the projector covers 148 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 176: ...13 Specifications 172 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 186: ...14 Pin configurations 182 R5905963 PROMETHEUS SERIES 09 03 2015 ...