3. Getting started
Barco – Hydra Compact – R5976568 – Revision 10 – February-2004
____________________________________________________________________________________________
3-3
The table below lists the names and functionality of the LED’s at the front of H
YDRA
C
OMPACT
:
number
name / meaning
state
meaning
[7] green
power /
ON - permanent
power supply and power modules OK
power failure
ON - blinking and
Buzzer is active
one or more power modules failed /
/
one or more power cords are disconnected
[8] green
A1 / power OK
K
ON - permanent
+3.3 V on the overlay board is OK
OFF
+3.3 V on the overlay board failed
[9] red
B1 /
power unit failed
reserved for future use
[10] green A2 / booting
ON - blinking
king
H
YDRA
C
OMPACT
gets configured
ON - permanent
H
YDRA
C
OMPACT
configuration was successful
[11] red
B2 / booting
failed
ON - blinking
H
YDRA
C
OMPACT
configuration failed
OFF
H
YDRA
C
OMPACT
configuration was successful
[12] green A3 /
software
heartbeat
ON - blinking
H
YDRA
C
OMPACT
software is running
(starts running after successful configuration)
OFF
H
YDRA
C
OMPACT
software is down
[13] red
B3 / system error
ystem error
ON - blinking
operation error occurred
OFF
no operation error
Table 3-1
Allocation of LEDs on front of H
YDRA
C
OMPACT
Details concerning
software heartbeat
[12] and
] and
system errors
[13] can be seen in the
Module Status
and
Wall
Alarms
list respectively, please refer to the sections
Module Status
and
Wall Alarms Area
in the iS
TUDIO
user’s manual.
Summary of Contents for Hydra Compact
Page 1: ......