4. Installation procedures
4.2
Overview cabling FLX system with FLX-24 pixels
Cabling diagram
1
6
4
3
7
11
8
10
9
2
5
Image 4-1
1
NNI Data cable with latch (HDMI). Connection with the output port of the DX-700 Digitizer. Up to 10 meter or with NNI Fiberlink up to 150 meter.
2
NNI Data cable with latch (HDMI). Connection with the next FLX-NNI Controller. Up to 10 meter.
3
FLX Data cable with IP66 protection shells (RJ45). Connection with FLX-HUB input port. Up to 100 meter. Standard FTP network cable Cat 5 can be used if equipped
with IP66 protection shells.
4
FLX Power Cable. Up to 50 meter.
5
FLX Power Splitter Cable. From 1 to 4.
6
FLX-HUB output extension cable. Up to 20 meter till FLX-24 converter cable.
7
FLX-24 converter cable. Required between each FLX-HUB output port and
fi
rst FLX-24 connector string.
8
FLX-24 connector string. Up to 256 FLX-24 pixels per FLX-HUB output port.
9
FLX-S carrier. Up to 256 FLX-24 pixels per FLX-HUB output port.
10
FLX-24 extension cable. Up to 5 meter to the next string.
11
FLX-24 extension cable. Up to 5 meter between two strings.
An NNI Fiberlink can be used between the digitizer and FLX-NNI Controller units.
C
AUTION
:
The last unused output plug in the connector string must be sealed with a protection cap to meet
the IP65 rating of the system.
R59770420 FLX-24 21/12/2009
45
Summary of Contents for FLX-24
Page 1: ...FLX 24 Installation manual R59770420 00 21 12 2009...
Page 6: ...Table of contents 2 R59770420 FLX 24 21 12 2009...
Page 46: ...3 Components of an FLX display system 42 R59770420 FLX 24 21 12 2009...
Page 56: ...4 Installation procedures Image 4 11 52 R59770420 FLX 24 21 12 2009...
Page 72: ...B Specifications 68 R59770420 FLX 24 21 12 2009...