3. Components of an FLX display system
BARCO FLX
►
HUBs
BARCO FLX
►
Next HUB
HUB OUT 1
Previous HUB
Patterns
Info
Power off HUBs
Address:
12
Back
Via this menu you can select one of the connected FLX-HUB units
to set a local pattern or retrieve information. Furthermore, an
option is provided to switch the power of all connected FLX-HUB
units on or off.
BARCO FLX
►
HUBs
►
Patterns
BARCO FLX
►
Pattern off
HUBs
Red
Patterns
Green
Blue
White
String colors
Address:
12
Running pattern
▼
This menu allows you to activate one of the local test patterns for
the connected FLX-HUB units.
The arrow
▼
, in the lower right corner, which is pointing
downwards indicates that the list is longer than the LCD display.
Use the navigation buttons to scroll down to see the next items in
the list. An arrow
▲
in the upper right corner will appear.
BARCO FLX
►
HUBs
►
Patterns
BARCO FLX
White
▲
HUBs
String colors
Patterns
Running pattern
Running pixel
Flying pixel
Address:
12
►
Back
The last item in the list is ’Back’ which can be used to go to the
previous menu.
Note that the Patterns menu does not automatically return to the
root menu after 30 seconds of inactivity.
BARCO FLX
►
HUBs
►
Info
HUB OUT 1 Info
S/N: 123456789
Versions:
Software:
01.00.0
Backup:
01.00.0
Firmware:
01.00.0
Backup:
01.00.0
Pixel type:
FLX-24
Pixels:
256,128,128,64,64,64,64,4
This menu displays information about the selected FLX-HUB
such as serial number, software/
fi
rmware versions, connected
pixel type and the number of pixels connected per FLX-HUB
output port.
BARCO FLX
►
HUBs
►
Power off
BARCO FLX
POWER OFF
HUBs
ALL HUBS
Power off
►
Yes
Back
Address:
12
This option allows you to switch off the power of all FLX-HUB
units connected with this FLX-NNI Controller.
BARCO FLX
►
HUBs
►
Power on
BARCO FLX
POWER ON
HUBs
ALL HUBS
Power on
►
Yes
Back
Address:
12
This option allows you to switch on the power of all FLX-HUB
units connected with this FLX-NNI Controller.
Other important popup messages
! BACKUP FIRMWARE !
This message appears in case the FLX-NNI Controller unit runs
with backup
fi
rmware. This means that the main
fi
rmware is
corrupt and should be updated. Updating the
fi
rmware of the
FLX-NNI Controller unit has to be done with the Director toolset.
See user guide of the Director toolset for detailed instructions.
Note that the functionality of an FLX-NNI Controller unit which
runs with backup
fi
rmware is almost completely disabled. Only
the
fi
rmware can be updated.
28
R59770420 FLX-24 21/12/2009
Summary of Contents for FLX-24
Page 1: ...FLX 24 Installation manual R59770420 00 21 12 2009...
Page 6: ...Table of contents 2 R59770420 FLX 24 21 12 2009...
Page 46: ...3 Components of an FLX display system 42 R59770420 FLX 24 21 12 2009...
Page 56: ...4 Installation procedures Image 4 11 52 R59770420 FLX 24 21 12 2009...
Page 72: ...B Specifications 68 R59770420 FLX 24 21 12 2009...