3. Components of an FLX display system
Image 3-21
19” rack mounting bracket for dual FLX-HUB.
Image 3-22
Rental mounting bracket (
R9863020
: 2 pieces).
Image 3-23
Fixed mounting bracket (
R9863030
: 4 pieces).
Cables used with the FLX-HUB
See the chapters about FLX-NNI Controller, DPR-2700 power system and FLX-24 pixel for information of cables used with the
FLX-HUB.
FLX-HUB input port diagnostic LED
Input LED
Situation
Action
Off
1.
The input port (RJ45 socket) of the
FLX-HUB is not connected with the
FLX-NNI Controller.
2.
The power of the FLX-HUB is
switched off. Note that in this case
all FLX-HUB units connected with
the FLX-NNI Controller are switched
off.
1.
Check the cabling of the FLX-HUB.
2.
Switch on the power of the FLX-HUB
via the user interface of the FLX-NNI
Controller or use the Director toolset.
Red
fl
ashing
Normal operation.
(no action required)
Flashing once + pause
The FLX-HUB runs with backup
fi
rmware.
The normal
fi
rmware is corrupt. This
situation may occur after an unsuccessful
(interrupted)
fi
rmware update with the
Director toolset. Note that the FLX-HUB
remains full operational.
Update the
fi
rmware of the FLX-HUB
using the Director toolset. Note that (at
least) all FLX-HUB units connected with
FLX-NNI Controller will be updated.
Flashing twice + pause
The FLX-HUB runs with backup software.
The normal software is corrupt. This
situation may occur after an unsuccessful
(interrupted) software update with the
Director toolset. Note that the FLX-HUB
remains full operational.
Update the software of the FLX-HUB
using the Director toolset. Note that (at
least) all FLX-HUB units connected with
FLX-NNI Controller will be updated.
Flashing fast
The FLX-HUB runs in ’boot loader’. This
is really an exceptional situation.
Replace the FLX-HUB unit and send the
malfunction unit back to factory for repair.
FLX-HUB output port diagnostic LED(s)
Output LED
Situation
Action
Off
1.
The input port (RJ45 socket) of the
FLX-HUB is not connected with the
FLX-NNI Controller.
2.
The power of the FLX-HUB is
switched off. Note that in this case
all FLX-HUB units connected with
the FLX-NNI Controller are switched
off. The diagnostic LED of the input
port remains off as well.
3.
No power voltage available on the
FLX-HUB. The diagnostic LED of
all output ports remain off and the
diagnostic LED of the input port is
fl
ashing.
1.
Check the data cabling (RJ45
socket) between the FLX-HUB and
the FLX-NNI Controller.
2.
Switch on the power of the FLX-HUB
via the user interface of the FLX-NNI
Controller or via the Director toolset.
3.
Check the power cabling between
the FLX-HUB and the DPR-2700
power system (PSU). Make sure that
the PSU is switched on an function
normally.
4.
Check if the load breaker of this
circuit in the PSU DPR-2700 is
switched on. See manual of the
R59770420 FLX-24 21/12/2009
31
Summary of Contents for FLX-24
Page 1: ...FLX 24 Installation manual R59770420 00 21 12 2009...
Page 6: ...Table of contents 2 R59770420 FLX 24 21 12 2009...
Page 46: ...3 Components of an FLX display system 42 R59770420 FLX 24 21 12 2009...
Page 56: ...4 Installation procedures Image 4 11 52 R59770420 FLX 24 21 12 2009...
Page 72: ...B Specifications 68 R59770420 FLX 24 21 12 2009...