3. Components of an FLX display system
BARCO FLX
►
This controller
►
String con
fi
g
BARCO FLX
►
Default config
This controller
Restore
String config
Back
Address:
12
The FLX-NNI Controller contains a default pixel string
con
fi
guration. This default con
fi
guration consist of 64 lines of 256
pixels. The
fi
rst 8 lines are applied to the data output port 1 (OUT
1), the next 8 to port 2 (OUT 2) and so on. The
fi
rst line on each
port goes to the
fi
rst output of its connected HUB. The second line
to the second output and so on up to eight.
This default line/pixel con
fi
guration allows to view content or test
patterns on the pixels connected with the FLX-NNI Controller.
The content displayed will be mixed up because the physical
location of the pixels does probably not match with the default
con
fi
guration.
LOADING! PLEASE WAIT ...
Note that the pixel string con
fi
guration, which was set by the
Director toolset, is stored in the
fl
ash memory of the FLX-NNI
Controller and thus remains available for restoring.
This message will appear during the ’Restore’ action.
BARCO FLX
►
This controller
►
String con
fi
g
►
Default con
fi
g
BARCO FLX
Load will override
This controller
the active config
String config
until power off/on
Default config
or Restore
►
Load now
Address:
12
Back
This menu allows you to start loading the default con
fi
guration.
Note that the default pixel string con
fi
guration will overrule
the active pixel string con
fi
guration which was set by the
Director toolset.
Only a restore action or a power off/on action will retrieve the
original pixel string con
fi
guration set by the Director toolset.
LOADING! PLEASE WAIT ...
Loading in progress ....
Calculation Creative Mask ...
Loading in progress ....
Calculation Creative Map ...
Loading in progress ....
Once the default string con
fi
guration is loaded, the ’String con
fi
g’
menu is displayed.
BARCO FLX
►
This controller
►
Link Errors
BARCO FLX
IN : 0
This controller
TRU1:0
Link Errors
TRU2:0
►
Reset
Back
Address:
12
This menu displays the counted link errors of the data IN and
data TRU connections of the FLX-NNI Controller. This is very
helpful if you see for example sparkles on the screen, or if the
communication seems to work hardly. On the LCD-display,
you see the number of errors on the input and the two output
connections. 0 means no errors, 65535 means maximum number
of errors. The error counter increments, if errors are detected,
until you press Reset (counting restarts from 0).
REMARK: A not-connected data IN port will always display
maximum number of errors (65535; just ignore this).
TIP: It may be helpful to count the errors over a very long period
of time in case errors occur exceptional. The menu doesn’t
disappear after a given time. If after a long period the error
counter is still zero, you can conclude that this path is OK.
26
R59770420 FLX-24 21/12/2009
Summary of Contents for FLX-24
Page 1: ...FLX 24 Installation manual R59770420 00 21 12 2009...
Page 6: ...Table of contents 2 R59770420 FLX 24 21 12 2009...
Page 46: ...3 Components of an FLX display system 42 R59770420 FLX 24 21 12 2009...
Page 56: ...4 Installation procedures Image 4 11 52 R59770420 FLX 24 21 12 2009...
Page 72: ...B Specifications 68 R59770420 FLX 24 21 12 2009...