3. Components of an FLX display system
Image 3-30
FLX male power plug (
R9856150
)
Image 3-31
FLX female power plug (
R9856160
)
FLX power cable speci
fi
cations
Voltage
54V, secundary, isolated from mains.
Current
16A at ambient of 45°C, free in the air or lying on a surface.
# wires
16 wires black, numbers 1-16 printed in white.
1 wire yellow/green
Cross-sectional of 1 wire
3 mm² (12AWG)
Operating temp
-30°C / +60 °C
Storage temp
-40°C / +85°C
Storage humidity
0 – 95 %
UV resistant
Yes
All weather resistant
Yes
Color
Black
Flammability rating
VW-1
Hazardous materials
RoHS compliant
Approvals
UL / CSA
Outer markings
1.
Name
2.
UL approved with
fi
le number or logo
3.
Maximum temperature
4.
voltage rating
5.
VW-1