4. Lamp & Lamp House
Image 4-10
6. Place the xenon lamp into a protective container or wrap a protective cloth around the xenon lamp prior to proceed with this
procedure.
7. Remove the anode wire lug from the anode socket. Use for that two open end wrenches of 17 mm. Hold one nut (reference
7) with one wrench while releasing the other nut (reference 4) with the other wrench. Note that a plain washer (reference 5) is
provided between the lock nut (reference 4) and the anode wire lug (reference 6).
5
7
7
6
4
4
Image 4-11
Note:
The electrical connection pins of older Lamp Houses may contain two
fl
at washers, one on each side of the wire lug. New
Lamp Houses can contain only one
fl
at washer due to the shorter thread clearance of the new improved connection pins.
8. Remove the cathode lamp adaptor (reference 11) from the xenon lamp (reference 13) as illustrated. Use a 5 mm Allen wrench
to release the adaptor
fi
xation screw (reference 12) of the adaptor.
12
12
11
13
Image 4-12
R5905050 DP2K C-SERIES 10/07/2012
27