4. Lamp & Lamp House
2,5 Nm
10
Image 4-21
Fasten cathode side
10.Check the cathode connection inside the Lamp House. Use a 17 mm open-end wrench to hold the
fi
rst nut while fastening the
second nut on the rod with a torque of
9 Nm
(6,64 lbf*ft) using a torque wrench with 17 mm hexagon socket. Ensure that there
is a
fl
at washer (reference 3) between the lock nut and the wire lug.
Caution:
This cathode connection must be checked with every lamp change!
Caution:
Do not tighten the
fi
rst nut (reference 1) against the connector housing. There must be some play (1 mm maximum).
This is important to insert the Lamp House smoothly into the projector.
1
2
3
4
9Nm
Image 4-22
Check cathode connection
Note:
The electrical connection pins of older Lamp Houses may contain two
fl
at washers, one on each side of the wire lug. New
Lamp Houses can contain only one
fl
at washer due to the shorter thread clearance of the new improved connection pins.
11.Reinstall the side cover of the Lamp House as illustrated.
Note:
Please ensure that the thumb screws turning wires are
fl
ash with the cover or interference will occur while inserting the
Lamp House into the projector.
32
R5905050 DP2K C-SERIES 10/07/2012
Summary of Contents for DP2K-12C
Page 1: ...DP2K C series Installation manual For DP2K 12C DP2K 15C DP2K 20C R5905050 04 10 07 2012...
Page 6: ......
Page 64: ...8 Starting up 58 R5905050 DP2K C SERIES 10 07 2012...
Page 92: ...11 Maintenance 86 R5905050 DP2K C SERIES 10 07 2012...
Page 104: ...13 Specifications 98 R5905050 DP2K C SERIES 10 07 2012...
Page 108: ...A Pin configurations 102 R5905050 DP2K C SERIES 10 07 2012...