Projector setup
4-4
5976065 BARCOCINE 8 08022000
Baud Rate for communication with a computer
The communication speed between the projector and the computer has 8 possible settings. With DIP Switch No. 6, No.7 and No.8
of the 8 DIP switches on the controller board, labelled as ‘Baud rate code (sum)’, it is possible to select the baud rate (communication
speed). Each DIP switch has its own decimal value. The sum of the values associated to those DIP switches gives the baud rate
code. Each baud rate code corresponds an communication speed.
Position of DIP switches and baud rate codes :
1
2
3
4
5
6
7
8
OFF ON
0
1
Baud rate
DIP switches
4
2
1
More information about computer communication with the projector is available in the Projector Control Software manual.
Password mode
With DIP Switch No.5 of the second set of 8 DIP switches on the controller board, the projector adjustments can be protected with
a password. When the password feature is enabled, the user has to enter a password before he can enter the adjustment mode
(For more information about password setting and reprogramming the password, see Installation Adjustment).
When the password menus are disabled (adjust mode is unprotected), the adjust mode can be selected by pressing the
<ADJUST>
key. This position of the DIP switch is useful for qualified service technicians because they do not need a password to enter the adjust
mode.
Position of DIP Switch No.5 :
O N :
password mode enabled.
OFF
:
password mode disabled.
Factory preset password mode : OFF.
Factory preset baud rate = 9600
Password
mode
1
2
3
4
5
6
7
8
OFF ON
0
1
Binary Baud rate code Speed
000
0
110
001
1
150
010
2
300
011
3
600
100
4
1200
101
5
2400
110
6
4800
111
7
9600