AC power connection
5-3
5976065 BARCOCINE 8 08022000
Power selector plug
Fuses
AC Power
input board
Power selector on 230V
Power selector on 120V
230V
120V
2
3
Fuses
Warning !
For continued protection against fire hazard :
•
Replace with the same type of fuse.
•
Refer replacement to qualified service personnel.
AC power Fuses
Order Number
230 Vac
T6.3A/250V (2x)
R314145
120 Vac
T10A/250V (2x)
R314154
Switching on
The projector is switched ON using the power (mains) switch ON/OFF.
Pressed : ON state
Not pressed : OFF state
The projector can start now in :
- Operational mode (picture displayed)
- Stand by mode
Depending on the position of the 'Power up' dip switch on the controller unit. This DIP switch is set during installation by a qualified
technician. If you want to change this start up mode, call a qualified techician.
Start up in Operational Mode
The projector can start up with the selected source or
the projector can start up with a warm up cycle message (menu 1).
PROJECTOR WARM UP
A FULL WHITE PATTERN WILL BE
GENERATED FOR 20 MIN.
FOR IMMEDIATE USE OF THE
PROJCTOR, PRESS <EXIT>
WARNING : SKIPPING THIS
PROCEDURE CAN REDUCE THE
INITIAL PICTURE QUALITY OF THE
PROJECTED IMAGE;
YOU CAN ADJUST THE IMAGE
DIMENSTIONS WITH THE ARROW
KEYS TO AVOID SCANNING ON
THE EDGES OF THE CRT'S;
THIS OPTION CAN BE DISABLED IN
THE SERVICE MENU
with <ENTER>
<EXIT> to return
menu 1
When this warm up cycle message appears on the screen, the menu offers the possiblity to start with this 20 minutes taking
warm up periode (press ENTER) or to skip this cycle (press EXIT).
Note : This warm up periode is built in so that the projector can reach its maximum specifications and minimize all distortions.
When starting this warm up period, a full white image is shifted on the CRT faceplate to avoid a burn in. Every 30 seconds a
text box will be displayed on another place on the screen with the remaining time to go.
To interrupt the warm up period, handle as follow :
1
Press EXIT, the warm up menu will be redisplayed with the remaining time indication.
2
Press EXIT again to quit the warm up cycle and to display the source.