M
Minimum insulation thickness
to combustible walls
Refer to chapter
5.3.7
for de-
tailed instructions
• side wall
• back wall
• floor
• ceiling
• 100 mm
• 100 mm
• 30 mm
• 40 mm
• 100 mm
• 100 mm
• 30 mm
• 40 mm
Used materials
• Combustion chamber side
panels
Cast iron
Cast iron
• Combustion chamber insu-
lation
Vermiculite 750 kg/m
3
Vermiculite 750 kg/m
3
• Combustion floor and grate Steel
Steel
• Lower baffle
Heat resistant ceramic 2000
kg/m
3
Heat resistant ceramic 2000
kg/m
3
• Upper baffle
Vermiculite 750 kg/m
3
Vermiculite 750 kg/m
3
Combustion air supply
Pipe connection with diameter
of 125 mm on the appliance or
3 holes with diameter of 125
mm on the optional convection
ventilator / combustion air inlet
box
Pipe connection with diameter
of 125 mm on the appliance or
3 holes with diameter of 125
mm on the optional convection
ventilator / combustion air inlet
box
Available options
• Convection ventilator / com-
bustion air inlet box
• Combustion air inlet box
• Set of 2 adjustable height
frames
• Fire screen
• Convection ventilator / com-
bustion air inlet box
• Combustion air inlet box
• Set of 2 adjustable height
frames
• Fire screen
• Opti-Air combustion control
Electrical energy consumption:
• Convection ventilator
• Opt.-Air combustion control
• 69 W; 230 VAC
• not applicable
• 69 W; 230 VAC
• adapter 230VAC / 6VDC
The specific precautions that
shall be taken when the local
space heater is assembled, in-
stalled or maintained, are listed
in the attached documents:
• Installation and mainte-
nance manual
• User manual
• Installation and mainte-
nance manual
• User manual
Technical data
Evolux 100-45
33
Summary of Contents for Evolux 100-45
Page 1: ...I Installation and maintenance manual Evolux 100 45 Serial number Production date...
Page 35: ...8 8 Dimensions 8 1 Evolux 100 45 with 3 sided frame Dimensions Evolux 100 45 35...
Page 36: ...8 8 2 Evolux 100 45 with 3 sided frame and convection casing Dimensions 36 Evolux 100 45...
Page 39: ...8 8 5 Evolux 100 45 with 3 sided frame and fire screen Dimensions Evolux 100 45 39...
Page 40: ...8 8 6 Evolux 100 45 with 4 sided frame Dimensions 40 Evolux 100 45...
Page 42: ...8 8 8 Evolux 100 45 with 4 sided frame and convection casing Dimensions 42 Evolux 100 45...
Page 44: ...8 8 10 Evolux 100 45 with 4 sided frame and fire screen Dimensions 44 Evolux 100 45...