A
Aligning with adjustable height frame
1. Set the frames to the required height.
Use a 10 mm socket spanner for the
4 screws.
Caution:
Make sure each frame is attached with all 4 screws.
2. Adjust the adjustable feet. Use a 13 mm fork spanner.
3. Make sure that the appliance is installed horizontally. Use a spirit level.
5.3.3
Connect the flue gas pipe
The appliance can be connected to steel pipes, double-walled insulated stainless steel
flues and flexible stainless steel flues with an outside diameter of 250 mm.
Caution:
• During operation of the appliance the outer side of the flue system
becomes hot. Refer to the installation instructions of the flue system for
safe installation. Follow these instructions with regard to safe distances to
combustible material.
If the appliance is installed on an unlined, masonry flue with a large diameter, consider
using a flue lining system to improve the performance of the appliance.
It is possible to connect the appliance on a flue with an inner diameter of minimum
200mm. Use a correct adapter on the flue connector.
Important:
If the appliance is fired with the door closed at all times, it is possible to use a
flue with a diameter of 200 mm. If not, use a flue with a diameter of 250 mm
1. Connect the flue to the flue gas connection on the appliance. If necessary use a steel
flue adaptor.
2. If a flexible stainless steel flue is used, secure the flue connection with 2 clamps.
3. If the flue is connected to an existing (masonry) chimney, make sure that the gap
between the flue and the existing chimney is sealed, with ceramic wool or any other
applicable component (ask your flue system supplier for advice)
4. Make sure that all mechanical connections of the flue system are correctly used.
5. Make sure that all of the flue system is gas-tight,
6. Insulate any non-insulated pipes with ceramic insulation wool. Refer to
5.3.6
for the
material requirements.
Installation
Evolux 100-45
19
Summary of Contents for Evolux 100-45
Page 1: ...I Installation and maintenance manual Evolux 100 45 Serial number Production date...
Page 35: ...8 8 Dimensions 8 1 Evolux 100 45 with 3 sided frame Dimensions Evolux 100 45 35...
Page 36: ...8 8 2 Evolux 100 45 with 3 sided frame and convection casing Dimensions 36 Evolux 100 45...
Page 39: ...8 8 5 Evolux 100 45 with 3 sided frame and fire screen Dimensions Evolux 100 45 39...
Page 40: ...8 8 6 Evolux 100 45 with 4 sided frame Dimensions 40 Evolux 100 45...
Page 42: ...8 8 8 Evolux 100 45 with 4 sided frame and convection casing Dimensions 42 Evolux 100 45...
Page 44: ...8 8 10 Evolux 100 45 with 4 sided frame and fire screen Dimensions 44 Evolux 100 45...