5.1
Installation requirements
5.1.1
General requirements
• Make sure the floor is made of concrete or a solid pedestal of non-combustible
material.
• Make sure the floor can support the weight of the appliance. Refer to chapter
7
for the
weight of the appliance.
• Make sure that the floor temperatures below and in front of the appliance cannot be
higher than 85 °C, during use of the appliance.
The graph shows the minimum depth of a non-combustible floor in front of the
appliance in relation to the installation height of the appliance. If the underside of the
door is 30 cm above the floor, the minimum depth of the non-combustible floor is
approx. 24 cm.
• The non-combustible floor must have a width that extends at least 150 mm from each
side of the appliance.
• Make sure the room where the appliance is installed is properly ventilated.
5.1.2
Requirements on the installation of the appliance
• Do not install the appliance against a combustible rear wall or combustible side wall.
• The appliance must be installed minimum 10 cm from a non-combustible wall.
• If a wooden beam is present above the appliance, make sure it is protected against
direct heat radiation. Make sure to put an insulation plate with a thickness of minimum
30 mm between the wooden beam and the appliance, with an air gap of minimum 1
cm between the insulation plate and the wooden beam.
• Make sure that combustion air can flow into the appliance without obstruction.
• If the appliance is equipped with the optional convection ventilator, the combustion air
must be supplied from outside through a flexible aluminum pipe to the appliance.
• If the appliance is equipped with a convection ventilator and/or Opti-Air, there must be
1 or 2 wall sockets with earth connection. These sockets must be accessible at all
times.
Installation
Evolux 100-45
15
Summary of Contents for Evolux 100-45
Page 1: ...I Installation and maintenance manual Evolux 100 45 Serial number Production date...
Page 35: ...8 8 Dimensions 8 1 Evolux 100 45 with 3 sided frame Dimensions Evolux 100 45 35...
Page 36: ...8 8 2 Evolux 100 45 with 3 sided frame and convection casing Dimensions 36 Evolux 100 45...
Page 39: ...8 8 5 Evolux 100 45 with 3 sided frame and fire screen Dimensions Evolux 100 45 39...
Page 40: ...8 8 6 Evolux 100 45 with 4 sided frame Dimensions 40 Evolux 100 45...
Page 42: ...8 8 8 Evolux 100 45 with 4 sided frame and convection casing Dimensions 42 Evolux 100 45...
Page 44: ...8 8 10 Evolux 100 45 with 4 sided frame and fire screen Dimensions 44 Evolux 100 45...