TTable 2: Installation against combustible or load-bearing walls
Item
Description
A Appliance
B Air gap
Space between appliance and insulation plate. Width of air gap at
least 3 mm
C Insulation plate
Plate of non-combustible material with a thickness of at least 100
mm and a thermal conductivity of at least 0.10 W/m.K
D Air gap
Space between insulation plate and wall. Width of air gap at least 20
mm
E Wall
Existing side and/or rear wall made of combustible material or load-
bearing wall
Caution:
• Put a non-combustible insulating plate with a thickness of at least 40 mm
and a thermal conductivity of not more than 0.10 W/m.K on a distance of at
least 50 mm from a combustible ceiling.
Table 3: Installation against a combustible ceiling
Item
Description
A Appliance
B Ventilation air outlet
Outlet of heated air from the chimney breast
C Insulation plate
Plate of non-combustible material with a thickness of at least 40 mm
and a thermal conductivity of at least 0.10 W/m.K
D Air gap
Space between insulation plate and wall. Width of air gap at least 50
mm
E Ceiling
Existing ceiling made of combustible material
Installation
24
Evolux 100-45
Summary of Contents for Evolux 100-45
Page 1: ...I Installation and maintenance manual Evolux 100 45 Serial number Production date...
Page 35: ...8 8 Dimensions 8 1 Evolux 100 45 with 3 sided frame Dimensions Evolux 100 45 35...
Page 36: ...8 8 2 Evolux 100 45 with 3 sided frame and convection casing Dimensions 36 Evolux 100 45...
Page 39: ...8 8 5 Evolux 100 45 with 3 sided frame and fire screen Dimensions Evolux 100 45 39...
Page 40: ...8 8 6 Evolux 100 45 with 4 sided frame Dimensions 40 Evolux 100 45...
Page 42: ...8 8 8 Evolux 100 45 with 4 sided frame and convection casing Dimensions 42 Evolux 100 45...
Page 44: ...8 8 10 Evolux 100 45 with 4 sided frame and fire screen Dimensions 44 Evolux 100 45...