![B&R 5AP92D.1505-I00 User Manual Download Page 83](http://html1.mh-extra.com/html/bandr/5ap92d-1505-i00/5ap92d-1505-i00_user-manual_460482083.webp)
Technical data
Automation Panel 9xD - Hygienic design User's manual V 1.80
83
Model number
5AP99D.215C-B62
Features
Emergency stop
Type
Schlegel FRVK series
2)
Contact element
2x normally closed contact, 1x normally open contact
Optional operating elements
Quantity
2x prepared cutout
Operating conditions
Pollution degree per EN 61131-2
Pollution degree 2
Suitable for hygienic applications
Yes
Degree of protection per EN 60529
Back: IP66 (only with flange installed)
Front: IP69K
2)3)
Degree of protection per UL 50
Front: Type 4X indoor use only
Mechanical properties
Note
The housing is designed for installation on a Rittal CP-
S stainless steel flange (CP6664.500 or CP6664.000)
Housing
Material
Stainless steel 1.4301, smoothed
Front
Frame
Stainless steel 1.4301, smoothed
Panel overlay
Material
Polyester
Design
B&R design
Gasket
Silicone profile gasket between front and cover
Flange output
Upper and lower
Dimensions
Width
573.7 mm
Height
407.7 mm
Depth
143 mm (without emergency stop)
Weight
10,800 g
1)
At 25°C ambient temperature. Reducing the brightness by 50% can increase the half-brightness time by approximately 50%.
2)
Emergency stop according to manufacturer as of October 2019, limitation: nozzle spacing > 250 mm, standard requirement per ISO 20653:2013-02 (IPX9K)
100 - 150 mm
3)
Under a steam jet, however, the structured coating on the front can become loose. This only affects the appearance of the front; functionality is not impaired.
4.2.1.7.4 Dimensions
Figure 16: 5AP99D.215C-B62 - Dimensions
Information:
2D and 3D diagrams (DXF and STEP formats) can be downloaded from the B&R website (
).