7.4.3.5 Access rights
There are various options for parameter 2 depending on the configuration.
MIFARE access rights (parameter 2)
Config
Key_CMD
Key_EEPROM
Key_TEMP
Para2
6-byte key
Sector for key in reader's EEP-
ROM
Uses the temporarily stored key: Dummy value (0-63)
Table 37: MIFARE access rights (parameter 2)
"A" = Authentication with key A, "B" = Authentication with key B
Sector
= 0-63
Source or target block
= 0-254 (depending on type MIFARE 1K 0-63, MIFARE 4K 0-254,
with decrement, increment, restore, source block must be of type "value block")
Data and key
= 00 - FF (no leading "0x", bytes can optionally be separated by a space)
Value
= 4 byte including sign bit
All commands and parameters are in ASCII. Data is in 00h hex format.
Para1
Para2
Para3
Para4
Para5
Block (typically 3 - sector trail-
er)
Access rights for block 0 (data
block)
Access rights for block 1 (data
block)
Access rights for block 2 (data
block)
Access rights for block 3 (sec-
tor trailer)
Table 38: MIFARE access rights (5-byte parameters)
Value
RD
WR
INCR
DECREMENT / TRANSFER / RESTORE
Comment
0x00
A / B
A / B
A / B
A / B
Full access with every key (de-
fault factory setting)
0x01
A / B
B
-
-
0x02
A / B
-
-
-
0x03
A / B
B
B
A / B
Value block
0x04
A / B
-
-
A / B
Value block
0x05
B
-
-
-
0x06
B
B
-
-
0x07
-
-
-
-
No access
Table 39: MIFARE access rights - Parameters 2, 3 and 4 (data blocks)
If key B is read in the corresponding sector trailer, it cannot be used for authentication (all of the yellow rows in
the table above).
Consequences
: When the reader attempts to authenticate a block in a sector with Key B (access conditions
marked in gray), then the card will refuse all subsequent memory access following the authentication.
Value
Key A
Access bits
Key B
Comment
RD
WR
RD
WR
RD
WR
0x00
-
A
A
-
A
A
Key B can be read.
0x01
-
B
A / B
-
-
B
0x02
-
-
A
-
A
-
Key B can be read.
0x03
-
-
A / B
-
-
-
No access
0x04
-
A
A
A
A
A
Key B can be read (factory default).
0x05
-
-
A / B
B
-
-
0x06
-
B
A / B
B
-
B
0x07
-
-
A / B
-
-
-
No access
Table 40: MIFARE access rights - Parameter 5 (sector trailer)