•
An AIS SART icon is located on the chart in the position received from the AIS SART
•
An alarm message is displayed
If you have enabled the siren, the alarm message is followed by an audible alarm.
Ú
Note:
The icon is green if the received AIS SART data is a test and not an active message.
AIS SART alarm message
When data is received from an AIS SART, an alarm message is displayed. This message
includes the AIS SART’s unique MMSI number, and its position, distance, and bearing from
your vessel.
You have the following options:
•
Ignore the alarm
- The alarm is muted and the message closed. The alarm does not reappear
Ú
Note:
If you ignore the alarm, the AIS SART icon remains visible on your chart, and the
AIS SART remains in the Vessels list.
•
Save the waypoint
- The waypoint is saved to your waypoint list. This waypoint name is prefixed with MOB
AIS SART - followed by the unique MMSI number of the SART. For example, MOB AIS
SART - 12345678.
•
Activate the MOB function
- The display switches to a zoomed chart panel, centered on the AIS SART position
- The system creates an active route to the AIS SART position
Ú
Note:
If the MOB function is already active, this will be terminated and replaced by the
new route towards the AIS SART position!
Ú
Note:
If the AIS stops receiving the AIS SART message, the AIS SART remains in the
Vessels list for 10 minutes after it receives the last signal.
If you select the AIS SART icon on the chart panel, then you can see the AIS MOB details.
Vessel alarms
You can define several alarms to alert you if a target shows up within predefined range limits,
or if a previously identified target is lost.
108
AIS
| Zeus3 Operator Manual
Summary of Contents for Zeus3 Glass Helm
Page 1: ...ENGLISH Zeus3 Operator Manual www bandg com ...
Page 2: ......
Page 140: ... 988 11377 001 0980 ...