BVS ID-M1280xF1-xx-xxx
16
english
4.3.6 IIoT (Gigabit Ethernet)
The LAN interface meets the Ethernet standard in accordance with IEEE 802.3-2008 (up to 1 Gigabit). This
network connection is used to call up the web interface BVS Cockpit for the configuration. In addition, a
communication channel is available to control the image analysis and to call up the generated result values.
8-pin M12 socket, X-coded
Pin
Description
Function
1
BI_DA +
Bidirectional data, Pair A +
2
BI_DA –
Bidirectional data, Pair A –
3
BI_DB +
Bidirectional data, Pair B +
4
BI_DB –
Bidirectional data, Pair B +
5
BI_DD +
Bidirectional data, Pair D +
6
BI_DD –
Bidirectional data, Pair D –
7
BI_DC –
Bidirectional data, Pair C –
8
BI_DC +
Bidirectional data, Pair C +
4.3.7 I/O light
The I/O light interface provides 24 Volt and two I/O signals (I/O 2 & I/O 3). These I/Os, similar to the two I/Os at
the power plug connectors (see chapter
Power
), are equipped with a push-pull output stage and a PNP input.
5-pin M12 socket, A-coded
Pin
Description
Function
1
VP (+24 V
DC
)
Operating voltage
2
I/O
Digital output
3
GND
Ground
4
I/O
External light output / digital
output
5
Not used
None. Pin may not be used.
NOTE
The cable must correspond at least to category 5e in accordance with EIA/TIA-568.
Transfer in accordance with 1000BASE-T/100BASE-TX/10BASE-T is being supported.
Summary of Contents for BVS ID-M1280-F1 Series
Page 1: ...deutsch Betriebsanleitung english User s Guide BVS ID M1280 F1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Betriebsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 45: ...956114_AA DE K22 nderungen vorbehalten...
Page 46: ......
Page 47: ...english User s Guide BVS ID M1280xF1 xx xxx...
Page 48: ...www balluff com...