Error
Cause
Action
The
BVS ID
signals the error
status "System Error"
Internal system error - see
also the following entries in
this table
Possible approaches:
Power off the system and turn it on
again. Some error states can be
corrected with this.
Connect to the
BVS ID
SensorApp
software with a web browser and get
information about the cause of the
problem:
Pay attention to dialogs with
error messages.
Switch from monitor mode to
config mode.
Open the "
System Settings
"
dialog and select the "
System
"
page there.
Click on "
Download Log Files
"
in the "
Log files
" line. A page
with a list of the system log files
opens.
Open the "
System.log
" file and
navigate to the end of the file.
Look for the entry: "
Status
SystemError has been set.
" The
following entry provides
information about the cause of
the internal problem.
To proceed further, observe the
following information in this
table
If the error cannot be resolved using
the following instructions, contact
Technical Support.
NOTE
The error status "System Error" is
signaled as long as the internal
problem persists. The status is
automatically reset when the
internal problem no longer exists.
This error signal cannot be
influenced by the "Reset error"
command.
Summary of Contents for BVS ID-M1280-F1 Series
Page 1: ...deutsch Betriebsanleitung english User s Guide BVS ID M1280 F1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Betriebsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 45: ...956114_AA DE K22 nderungen vorbehalten...
Page 46: ......
Page 47: ...english User s Guide BVS ID M1280xF1 xx xxx...
Page 48: ...www balluff com...