BVS ID-M1280xF1-xx-xxx
14
english
4.3.1 Power
The power plug connector supplies the
BVS ID
with the operating voltage and offers one input as a trigger I/
O-24 V switching signal (I/O 0) for the connection with sensors, actuators or PLC.
4-pin M12 plug, A-coded
Pin
Description
Function
1
+24 V
DC
Operating voltage
2
I/O
Trigger input
3
GND
Ground
4
I/O
IO-Link protocol / SIO as a
digital output for the total
result of the inspection
program iteration (Mode
setting required by IO-Link
master)
These two inputs and outputs feature a push-pull output stage. This allows using the output signal for PNP logic
as well as NPN logic. The input stage always features PNP logic.
I/O 0 & I/O 1 (power plug connectors)
Operation as input
Voltage
Signal 0
0 to 5 V
< 2 mA
Signal 1
11 to 30 V
2 to 5 mA
Delay
< 160 μs
See also the guideline on digital inputs, EN 61131-2, Type 3.
Below are examples how inputs and outputs must be connected to obtain input and output function.
NOTE
The digital sensor inputs correspond to the guideline concerning inputs, EN 61131
‑
2,Type 3.
The maximum load on any output is 50 mA. The total current of the module must not exceed 4 A per
pin. The load or supply must be limited accordingly.
Summary of Contents for BVS ID-M1280-F1 Series
Page 1: ...deutsch Betriebsanleitung english User s Guide BVS ID M1280 F1 xx xxx...
Page 2: ...www balluff com...
Page 3: ...deutsch Betriebsanleitung BVS ID M1280xF1 xx xxx...
Page 4: ...www balluff com...
Page 45: ...956114_AA DE K22 nderungen vorbehalten...
Page 46: ......
Page 47: ...english User s Guide BVS ID M1280xF1 xx xxx...
Page 48: ...www balluff com...