BIS C-6021
Interface Information / Wiring Diagrams
To make the connections for the InterBus, the supply voltage and the digital input, connect
the pre-assembled cable to the processor. For additional wiring information, see the
following
.
Connect the read/write heads to the terminals for Head 1 and Head 2.
The BIS C-6021...ST8 processor is intended for use on the installation remote bus, which
provides the supply voltage over the bus. The BIS C-6021...ST9 processor is intended for use
on the remote bus, whereby the supply voltage for the processor is brought in through X1.
Connect the incoming I
NTER
B
US
cable to the I
NTER
B
US
input X3. Connect the outgoing
I
NTER
B
US
cable to the I
NTER
B
US
output X2.
If this remote bus station is the last one on the bus, the I
NTER
B
US
output X2 must be closed
off with a threaded cap to maintain the enclosure rating.
Please note the load capacity of the I
NTER
B
US
cable and verify during operation that the supply
voltage is maintained at the processor (see Technical Data for specifications).
Connecting on the
remote bus or
installation remote
bus
☞
C60_1-023_819395_0508_en.p65
76
76
E
Head 2 Head 1
X1
X2
X3
X5
X5
UL
CC
BA
RD
Head 1
Head 2
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
X4
Wiring diagram for
BIS C-6021...ST8
processor on
installation remote
bus
BIS C-6021...ST8
Interface Information / Wiring Diagrams (installation remote bus)
X1
, supply voltage and digital input
X2
, I
NTER
B
US
output
Function
ground FE
X3
, I
NTER
B
US
input
Pin
Function
1
not
connected
3
2
IN
4
+IN
Pin
Function
1
DO2
2
/DO2
3
DI2
4
/DI2
5
GND
9
/RBST
6
FE
7
+24 V
8
0 V
Pin
Function
1
DO1
2
/DO1
3
DI1
4
/DI1
5
GND1
6
FE
7
+24 V
8
0 V
X4
, Service interface
Pin
Function
1
2
TxD
3
GND
4
RxD