55
deutsch
55
E
Example No. 15
For configuring with
double bit header!
Read-out programmed configuration data:
Host:
1.)
Process subaddresses of the output buffer in the
order shown:
BIS C-60_1 Identification System:
2.)
Process subaddresses of the input buffer in the
order shown:
4.)
Process subaddresses of the output buffer:
3.)
Process subaddresses of the input buffer:
00
Hex
/07
Hex
Reset AA-Bit and AE-Bit
01
Hex
Command designator 05
Hex
00
Hex
/07
Hex
Set AV-Bit
00
Hex
/07
Hex
Set AA-Bit
01...06
Hex
Enter the 6 configuration bytes
00
Hex
/07
Hex
Set AE-Bit
01...06
Hex
Copy the 6 configuration bytes
Process subaddress of the output buffer:
00
Hex
/07
Hex
Reset AV-Bit
Function Description
Examples for protocol sequence
C60_1-023_819395_0508_en.p65
56
56
E
Read times from
data carrier to
processor in
static mode
(parametering:
2nd byte, bit 5 = 0,
without CRC_16 data
check)
The indicated times apply after the data carrier has been recognized. If the data carrier is not yet
recognized, an additional 45 ms for building the required energy field until the data carrier is recog-
nized must be added.
For double read and compare:
Data carrier with 32 byte blocks
Data carrier with 64 byte blocks
No. of bytes
Read time [ms]
No. of bytes
Read time [ms]
from 0 to 31
110
from 0 to 63
220
for each additional
32 bytes add
120
for each additional
64 bytes add
230
from 0 to 255
= 950
from 0 to 2047
= 7350
Including readback and compare:
Data carrier with 32 byte blocks
Data carrier with 64 byte blocks
No. of bytes
Write time [ms]
No. of bytes
Write time [ms]
from 0 to 31
110 + n * 10
from 0 to 63
220 + n * 10
for 32 bytes or more
y * 120 + n * 10
for 64 bytes or more
y * 230 + n * 10
n = number of contiguous bytes to write
y = number of blocks to be processed
Example: 17 bytes from address 187 have to be written. Data carrier with 32 bytes per block.
The blocks 5 and 6 will be processed since the start address 187 is in block 5 and the end
address 203 in block 6.
t = 2 * 120 + 17 * 10 = 410 ms
Write times from
processor to data
carrier in static
mode
(parametering:
2nd byte, bit 5 = 0,
without CRC_16 data
check)