Copy 17 bytes starting at data carrier address 10
(data carrier type with 32 byte block size)
:
Data from the data carrier in front of Head 1 are read and written to the same memory loca-
tion in the data carrier in front of Head 2. Data transmission can start even while the data
carrier in front of Head 1 is still being read. This is indicated by the TO-bit in the input buffer.
The bytes which are read are written to the data carrier in front of Head 2 during data trans-
mission (“toggling” TI-bit/TO-bit), and only then. The AE-bit is not set until the write procedure
on Head 2 is successfully concluded. Any errors which occur on Head 2 are indicated by the
AF-bit in the bit header for Head 1.
01
Hex
Command designator 11
Hex
02
Hex
Start address Low Byte 0A
Hex
03
Hex
Start address High Byte 00
Hex
04
Hex
No. of bytes Low Byte 11
Hex
05
Hex
No. of bytes High Byte 00
Hex
00
Hex
/07
Hex
CT-Bit to 0 (32 Byte block size),
set AV-Bit
00
Hex
/07
Hex
Set AA-Bit
01...06
Hex
Enter first 6 bytes of data
00
Hex
/07
Hex
Invert TO-Bit
01...06
Hex
Enter the second 6 data bytes
00
Hex
/07
Hex
Invert TO-Bit
01...06
Hex
Copy first 6 data bytes
Process subaddress of the output buffer:
00
Hex
/07
Hex
Invert TI-Bit
Example No. 8
Continued on next
.
BIS C-60_1 Identification System:
2.)
Process subaddresses of the input buffer in order
shown:
Host:
1.)
Process subaddresses of the output buffer in
order shown:
3.)
Process subaddresses of the input buffer:
4.)
Process subaddresses of the input buffer:
Function Description
Examples for protocol sequence
For configuring with
double bit header!
C60_1-023_819395_0508_en.p65
46
46
E
01...05
Hex
Enter the remaining 5 data bytes
00
Hex
/07
Hex
Invert TO-Bit
Example No. 8
(continued)
For configuring with
double bit header !
7.)
Process subaddresses of the input buffer:
8.)
Process subaddresses of the input buffer:
6.)
Process subaddresses of the input buffer:
5.)
Process subaddresses of the input buffer:
01...06
Hex
Copy second 6 data bytes
Process subaddress of the output buffer:
00
Hex
/07
Hex
Invert TI-Bit
01...05
Hex
Copy the remaining 5 data bytes
Process subaddress of the output buffer:
00
Hex
/07
Hex
Invert TI-Bit
00
Hex
/07
Hex
Set AE-Bit
Function Description
Examples for protocol sequence
BIS C-60_1 Identification System:
Host:
10.)
Process subaddresses of the input buffer:
9.)
Process subaddresses of the output buffer:
00
Hex
/07
Hex
Reset AV-Bit
00
Hex
/07
Hex
Reset AA-Bit and AE-Bit