www.balluff.com
9
english
4
Assembly, disassembly and connection (continued)
4.3
Equipment parts
If the BTL or connection housing is left individually or
disassembled in the plant, note the following:
– Leave connection terminal without power!
– Use cable shield to ground the BTL through the ground
terminal or connection housing.
– Use original equipment protection caps to protect from
contamination.
– Use additional securing of the protection caps
depending on the installation mounting position,
vibration, temperature etc.
– Protect any components and the protection cap left in
the plant from mechanical stress and damage.
4.4
Electrical Connection
The electrical connection is permanent and made using a
cable. For the connection assignments, see Tab. 4-1.
DANGER
Explosions
Connecting the BTL in an explosion hazard atmosphere
could result in explosions. This could result in personal
injury and equipment damage.
►
Connect only in non-EX zone areas or in a suitable
enclosure.
Note the information on shielding and cable
Wire color
Signal
Connection
Brown
BN 10…30 V
BTL on power
supply
Blue
BU GND
Green
GN RxD/TxD-N (A) IN
BTL on
PROFIBUS line
Red
RD RxD/TxD-P (B) IN
Black
BK
RxD/TxD-N (A) OUT Next PROFIBUS
slave or active
PROFIBUS
termination
resistor
White
WH RxD/TxD-P (B) OUT
Pink
PK
+5 V OUT
Active
PROFIBUS
termination
resistor
Gray
GY DGND OUT
Transparent
Shield
Tab. 4-1: Pin Assignments
The power consumption of the BTL must be
limited externally by the user to 4 W!
Bus termination
If the BTL is the last slave in the PROFIBUS line, an active
bus terminator must be installed (see Fig. 4-1).
Fig. 4-1:
390 Ω
220 Ω
390 Ω
+5 V OUT
DGND OUT
RxD/TxD-P (B) OUT
RxD/TxD-N (A) OUT
Bus termination
If the device is installed in the middle of the PROFIBUS
line, +5 V OUT and DGND OUT are not connected. Be
sure however to isolate with respect to ground and other
signals.
BAM PC-TL-020-K_ _/KA_ _-4
Connection cover for magnetostrictive linear position sensor
Summary of Contents for BAM PC-TL-020-K Series
Page 2: ...www balluff com...
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ...BAM PC TL 020 K_ _ 4 BAM PC TL 020 KA_ _ 4 Betriebsanleitung deutsch...
Page 8: ...www balluff com...
Page 21: ...BAM PC TL 020 K_ _ 4 BAM PC TL 020 KA_ _ 4 User s Guide english...
Page 22: ...www balluff com...
Page 35: ...BAM PC TL 020 K_ _ 4 BAM PC TL 020 KA_ _ 4 Notice d utilisation fran ais...
Page 36: ...www balluff com...
Page 49: ...BAM PC TL 020 K_ _ 4 BAM PC TL 020 KA_ _ 4 Manuale d uso italiano...
Page 50: ...www balluff com...
Page 63: ...BAM PC TL 020 K_ _ 4 BAM PC TL 020 KA_ _ 4 Manual de instrucciones espa ol...
Page 64: ...www balluff com...
Page 77: ...BAM PC TL 020 K_ _ 4 BAM PC TL 020 KA_ _ 4...
Page 78: ...www balluff com...
Page 90: ...14 9 1 1 2 3 4 1 2 3 4 9 1 9 BAM PC TL 020 K_ _ KA_ _ 4 931693 ZH G17...
Page 91: ...BAM PC TL 020 K_ _ 4 BAM PC TL 020 KA_ _ 4...
Page 92: ...www balluff com...
Page 104: ...14 9 1 1 2 3 4 1 2 3 4 P 9 1 9 BAM PC TL 020 K_ _ KA_ _ 4 931693 RU G17...
Page 105: ......