Care2
Installation Instructions
Care2 issue 7
29
2.9 J
ACK
S
OCKETS
2.9.1 Mounting Details
The Jack Socket should be mounted in a suitable single gang
backbox, deep enough to ensure the PCB & terminations will not
be damaged when the plate is fitted in place.
2.9.2 Connection Details
Figure 2.36 — Site Wiring Connections for Jack Socket
The termination blocks on the Jack Socket Plate are “Cage
Clamp” terminals to enable quick and secure connections.
The Jack Socket Plates are supplied with a 10K
Ω
termination
resistor fitted. This resistor must be fitted to enable the Console
to detect and monitor the jack socket.
N
OTE
: If multiple jack sockets are connected in a daisy chain
arrangement then the termination resistor MUST ONLY be fitted to the
final unit.
www.acornfiresecurity.com