36
Process to Add/Delete A Hose – Meter
On The Application Software:
1. Delete hose/meter from the Network Tree
2. Enter the Entity >> Hose – Meter
3. Delete the Hose/Meter to be replaced.
4. Enter the new Hose/Meter number.
a. The Hose address is the X.XXX.XXX.XXX number on the label visible when
battery door is detached from the meter.
5. Press MODIFY
6. Insert Hose/Meter in the Network Tree
Open The KPS program:
1. Double click on the KPS icon on bottom corner of the screen.
2. Under Edit click on the INIT
3. Minimize the KPS program (Note: DO NOT EXIT (X) the program)
The Program will automatically Re-initialize and download all of the system information to the
Zone Keypads.
It is suggested this process take place at the end of the day.
After completion of the programming, the normal Dispense Order process may be followed.