Masoneilan SVI II AP Digital Positioner Quick Start Guide
=
| 31
© 2020 Baker Hughes Company. All rights reserved
.
For the procedure to mount rotary and reciprocating valves,
refer to the Mounting Instructions contained in the valve’s
Mounting Box kit.
Mounting the SVI II AP on Rotary Valves
This section describes the procedure for mounting the SVI II
AP on rotary control valves that have less than 60° rotation,
such as a Masoneilan Camflex
TM
II or a Masoneilan Varimax
TM
.
13 shows a side view of a Camflex actuator and the SVI
II AP actuator mounting brackets.
Figure 13
Camflex with Mounting Bracket (Side View)
Mounting the SVI II AP on a Rotary Actuator
Tools required:
3
⁄
16" Hex Key
5
⁄
32" Hex Key
3 mm, 4 mm, 5 mm Hex Key
7
⁄
16" Wrench
To mount the SVI II AP:
1. Attach the SVI II AP rotary mounting bracket to the valve
actuator using two (2) 5
⁄
16 - 18 UNC flat-head cap screws.
In the preferred mounting position, the long end of the
mounting bracket is on your left when facing the actuator,
for any position of the valve and actuator.