is available for applications in which the customer is
unsure of the filter maintenance requirements. In these
cases, a preventive maintenance program may be
developed by monitoring the filters, without taking the
valve off line.
ATTENTION!
!
When servicing dual filters, procedures need to be in
place to perform a tag out / lock out of pilots under
pressure if they are in service.
E. Sensing Line Filter (Standard)
Consolidated 2900 Pilot Operated Relief valves come
configured directly from the factory with specially designed
filters to ensure long term operation. These filters should
be maintained based on the service conditions and
cleanliness of the media the valve will be exposed to.
Depending on the amount of contamination expected to be
introduced to the valve, these filters need to be regularly
inspected and replaced to ensure proper flow through
the valve is maintained. Regular maintenance intervals
should be established based on inspection of the filter at
the time of service. Heavy accumulation at the filter is an
indication that more frequent maintenance is needed. In
applications that call for exposure to a significant amount of
contaminants, our high capacity filters should be installed
that allow regular maintenance to be performed easily.
Please consult your factory authorized representatives
for details on how to obtain this configuration. The
high capacity filter configuration can be installed with
independent filters that allow the maintenance to be
performed while the valve remains in service.
Note: Tables 25 to 28 for replacement filter parts
information.
Figure 49: Dual Filter
XXII. 2900-40 Series POSRV Options (Cont.)
Figure 48: High Capacity Filter