B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
NEMA 3R Remote Driver
10W Solid State LED
Installation Instructions
120-208-
240-277
VOLT
120-208-
240-277
VOLT
COM
LAMP
1
LAMP
COM
1
LED
+
1
LED
1
LAMP
2
LAMP
COM
2
LED
+
2
LED
2
DIM
1
DIM
COM
1
DIM
+
1
DIM
1
DIM
2
DIM
COM
2
DIM
+
2
DIM
2
7.
Terminal Block Wiring
- Connect branch circuit to terminal block. Connect incoming ground to ground wire
provided on NEMA 3R housing. Connect secondary lamp leads to terminal block. See labels on terminal block
for additional information.
4. Connect conduit connector through female
threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal
connector threads and conduit with a suitable
sealant (Teflon tape, adhesive, etc.). Sealing
the conduit after knockouts are removed is
required to maintain warranty.
5. Pull branch circuit wiring necessary for
installation (By Others).
Dual Remote Driver
6. Pull secondary lamp leads necessary for
installation though dedicated conduit. (By
Others).
NOTE: Failure to comply with specific wiring
requirements will void product warranty.
8. Re-attach cover. Tighten cover screw.