IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS

Warning

Hot Surface

TOOLS

NEEDED: 

By Others

3/16” Allen wrench

360HD™ Knuckle Mounting System

Standard Adjustment

• 

Product must be installed by a qualified person in a manner 

consistent with its intended use and in compliance with the 

National Electrical Code, Canadian Electrical Code, and all Local 

and Provincial Codes. 

• 

Follow product label information and instructions.

• 

Qualified Personnel must perform all servicing or relamping of 

this product.

• 

Before wiring to power supply and during servicing or relamping, 

turn off power at fuse or circuit breaker before service.

• 

The use of accessory equipment not recommended by the 

manufacturer or installed contrary to instructions may cause an 

unsafe condition. The use of damaged components may cause 

an unsafe condition and void product warranty.

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY 

AND INSTALLATION INSTRUCTIONS

• 

Do not block light emanating from product in whole or part, 

as this may cause an unsafe condition.

• 

Never operate the fixture with missing or damaged lens.  

Lens must be cleaned on regular basis.

• 

Entire fixture may become extremely hot. Do not touch hot 

lens or fixture body. Do not touch the lamp at any time. Use 

a clean, dry, soft cloth to handle the lamp. Oil from skin may 

damage the lamp and cause it to rupture.

• 

Replace lamp only with correct wattage and type of lamp 

marked on fixture label.

• 

All gaskets, O-rings and sealing surfaces must be kept clean 

during installation and service; failure to do this may cause an 

unsafe condition and void product warranty. 

INSTRUCTIONS PERTAINING TO 

A RISK OF FIRE, OR INJURY TO 

PERSONS IMPORTANT SAFETY 

INSTRUCTIONS

Lighted lamp is HOT!

WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:  

Turn off/unplug and allow to cool before replacing lamp.  

Lamp gets HOT quickly! Contact only switch/plug when 

turning on.  

Do not touch hot lens, guard, or enclosure (see diagram/

picture).  

Keep lamp away from materials that may burn.  

Do no touch the lamp at any time. Use a soft cloth. Oil 

from skin may damage lamp.  

Do not operate the luminaire fitting with a missing or 

damaged shield.  

 

SAVE THESE INSTRUCTIONS

 

·  Suitable for wet locations ·  Additionally suitable for mounting within 4 ft. of the ground

IMPORTANT LISTINGS AND CERTIFICATIONS

3.  Use 3/16” Allen wrench to loosen (1) 1/4”-28 x 1-1/4” 

stainless steel black oxide socket head cap screw at 

the knuckle for vertical aiming purpose.

4.   Tighten (1) 3/8”-16 x 3/8” stainless steel black oxide 

set screw on the stem to secure horizontal aiming 

position. 

 

 

Tighten (1) 1/4”-28 x 1-1/4” stainless steel black 

oxide socket head cap screw to 24” minimum to 48” 

maximum pounds to secure vertical aiming position 

2.   Rotate fixture at base and aim fixture to desired  

horizontal location.

1. 

 Use 3/16” Allen wrench to slightly loosen 

 

(1) 3/8”-16 x 3/8” stainless steel black oxide set screw 

on the stem for 360° aiming purpose.

360HD™ Knuckle Mounting System

Warning: Do not over tighten set screw. Doing 

so will compromise O-ring seal and will void 

warranty. 

Summary of Contents for SARATOGA Series

Page 1: ...RM DRM Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code Canadian Electrical Code and all Local and Provi...

Page 2: ...rtight connections from remote driver to fixture leads using waterproof wire connectors By Others in splice location as per NEC Fixture Installation SARATOGA SERIES Remote Solid State LED Standard Ins...

Page 3: ...pull out end cap assembly LED is still attached to leads Detach heatsink from fixture body via quick disconnect Twist and gently pull away optic from optic holder Do not pull on connector or wiring H...

Page 4: ...refully pull out end cap assembly LED is still attached to leads Detach heatsink from fixture body via quick disconnect Loosen then remove two 2 8 32 screws from optic holder using 5 64 Allen wrench D...

Page 5: ...ome extremely hot Do not touch hot lens or fixture body Do not touch the lamp at any time Use a clean dry soft cloth to handle the lamp Oil from skin may damage the lamp and cause it to rupture Replac...

Page 6: ...ian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing o...

Page 7: ...wiring necessary for installation By Others Single Remote Driver 7 Connect branch circuit to terminal block Connect incoming ground to ground wire provided on NEMA 3R housing Connect secondary leads t...

Page 8: ...alant Teflon tape adhesive etc Sealing the conduit after knockouts are removed is required to maintain warranty 8 Re attach cover Tighten cover screw 5 Pull branch circuit wiring necessary for install...

Page 9: ...ck Connect incoming ground to ground wire provided on NEMA 3R housing Connect secondary lamp leads to terminal block See labels on terminal block for additional information 4 Connect conduit connector...

Page 10: ...nd wire provided on NEMA 3R housing Connect secondary lamp leads to terminal A See labels on terminal block for additional information 4 Connect conduit connector through female threaded conduit entry...

Page 11: ...an Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of...

Page 12: ...crews on Stability Flange to secure housing to EMT Remove excess EMT as needed 7 Per DIG IT Guide backfill the gap between the bottom of housing and bottom of hole with sand for drainage Housing Insta...

Page 13: ...e watertight connections using waterproof wire connectors provided to leads on the bottom of Patented HydroLock Barrier Plate Assembly See wiring diagram s 5 Turn HydroLock Barrier Plate clockwise to...

Page 14: ...EVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS 10 Remove any dirt or debris in O ring groove near top of housing Place O Ring inside of groove Failure to clean groove of debris w...

Page 15: ...n Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of...

Page 16: ...back of the UPM housing Feed safety cable through opposing ends of the connector Pull on wires to assure the connection is secure Leave enough slack in safety cable for tree growth Adjustments can be...

Page 17: ...ce with the National Electrical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protect...

Page 18: ...n 2 Pullbranchcircuitwiringnecessaryforinstallation By Others 3 Install universal mounting ring IMPORTANT Orientation of universal ring will affect orientation of UPM Take note of mounting plate holes...

Page 19: ...anadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servici...

Page 20: ...with 5 64 Allen wrench on outside of UPM housing to lock in place Figure C IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Installation In...

Page 21: ...rical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform...

Page 22: ...ack into place to renew seal integrity Installation Instructions PM2RM SURFACE MOUNT 10W Driver Housing 10 Make sure UPM housing gasket is free of any dirt or debris Attach the faceplate by tightening...

Page 23: ...Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of t...

Page 24: ...READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Ground Hot Neutral Installation Instructions PM2DRM TREE STRAP 10W Dual Driver Housing Red FIXTURE Hydrolock Plate Black D Driver White B...

Page 25: ...ical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform...

Page 26: ...orientation of UPM Take note of mounting plate holes indicated with arrows on the universal ring holes to mount UPM in correct orientation Installation Instructions PM2DRM ROUND CAMLOCK 10W Dual Drive...

Page 27: ...al Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform al...

Page 28: ...hed orientation as shown Figure A 5 Rotate housing 90 counter clockwise Figure B Tighten set screw with 5 64 Allen wrench on outside of UPM housing to lock in place Figure C Installation Instructions...

Page 29: ...ode Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all se...

Page 30: ...PM is designed as an installation aid and NOT a safety cable Do not add weight to or drop faceplate Red FIXTURE Hydrolock Plate Black Driver White Black Green Black White Hydrolock Plate Green Driver...