background image

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

RELEASED

2-26-19

REFERENCE

 

NUMBER

INS-2784-00

10"

(254mm)

"A/D" CAP

3" Dia.

(76mm)

2 11/16"

(68mm)

"B"/"E" CAP

(203mm)

8"

(76mm)

3" Dia.

2 11/16"

(68mm)

"C" CAP

(178mm)

7"

(76mm)

3" Dia.

Patented 360HD™

Mounting System

"B"/"E" CAP

3"

(76mm)

1"

(25mm)

"A"/"D" CAP

3"

(76mm)

5"

(127mm)

"C" CAP

2"

(51mm)

2 11/16"

(68mm)

1.  Mount fixture onto suitable enclosure according 

to designed lighting plan and NEC.

2.  Secure ½” NPS stem to mounting option. Secure 

with provided locknut if applicable. 

3.  Make watertight connections from remote 

driver to fixture leads using waterproof wire 

connectors (By Others) in splice location as per 

NEC. 

Fixture Installation

SARATOGA SERIES™

Remote - Solid State LED

Standard Installation 

5.   Rotate fixture at base and aim fixture to desired  

horizontal location.

6.   Tighten two (2) #8-32 stainless steel set screws 

on stem to secure horizontal aiming position

4.   Use 5/64” Allen wrench to slightly loosen two (2)  

#8-32 stainless steel set screws on the stem for 

360° aiming purpose.

7.   Use 5/32” Allen wrench to loosen #10-32 

stainless steel black oxide socket head cap screw 

at the knuckle for vertical aiming purpose. 

 

 

Tighten #10-32 stainless steel black oxide socket 

head cap screw to 15 in-lbs minimum to 30 in-lbs 

maximum to secure vertical aiming position.  

Warning: Do not over tighten set screw. 

Doing so will compromise O-ring seal and will 

void warranty. 

Summary of Contents for SARATOGA Series

Page 1: ...RM DRM Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code Canadian Electrical Code and all Local and Provi...

Page 2: ...rtight connections from remote driver to fixture leads using waterproof wire connectors By Others in splice location as per NEC Fixture Installation SARATOGA SERIES Remote Solid State LED Standard Ins...

Page 3: ...pull out end cap assembly LED is still attached to leads Detach heatsink from fixture body via quick disconnect Twist and gently pull away optic from optic holder Do not pull on connector or wiring H...

Page 4: ...refully pull out end cap assembly LED is still attached to leads Detach heatsink from fixture body via quick disconnect Loosen then remove two 2 8 32 screws from optic holder using 5 64 Allen wrench D...

Page 5: ...ome extremely hot Do not touch hot lens or fixture body Do not touch the lamp at any time Use a clean dry soft cloth to handle the lamp Oil from skin may damage the lamp and cause it to rupture Replac...

Page 6: ...ian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing o...

Page 7: ...wiring necessary for installation By Others Single Remote Driver 7 Connect branch circuit to terminal block Connect incoming ground to ground wire provided on NEMA 3R housing Connect secondary leads t...

Page 8: ...alant Teflon tape adhesive etc Sealing the conduit after knockouts are removed is required to maintain warranty 8 Re attach cover Tighten cover screw 5 Pull branch circuit wiring necessary for install...

Page 9: ...ck Connect incoming ground to ground wire provided on NEMA 3R housing Connect secondary lamp leads to terminal block See labels on terminal block for additional information 4 Connect conduit connector...

Page 10: ...nd wire provided on NEMA 3R housing Connect secondary lamp leads to terminal A See labels on terminal block for additional information 4 Connect conduit connector through female threaded conduit entry...

Page 11: ...an Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of...

Page 12: ...crews on Stability Flange to secure housing to EMT Remove excess EMT as needed 7 Per DIG IT Guide backfill the gap between the bottom of housing and bottom of hole with sand for drainage Housing Insta...

Page 13: ...e watertight connections using waterproof wire connectors provided to leads on the bottom of Patented HydroLock Barrier Plate Assembly See wiring diagram s 5 Turn HydroLock Barrier Plate clockwise to...

Page 14: ...EVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS 10 Remove any dirt or debris in O ring groove near top of housing Place O Ring inside of groove Failure to clean groove of debris w...

Page 15: ...n Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of...

Page 16: ...back of the UPM housing Feed safety cable through opposing ends of the connector Pull on wires to assure the connection is secure Leave enough slack in safety cable for tree growth Adjustments can be...

Page 17: ...ce with the National Electrical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protect...

Page 18: ...n 2 Pullbranchcircuitwiringnecessaryforinstallation By Others 3 Install universal mounting ring IMPORTANT Orientation of universal ring will affect orientation of UPM Take note of mounting plate holes...

Page 19: ...anadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servici...

Page 20: ...with 5 64 Allen wrench on outside of UPM housing to lock in place Figure C IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Installation In...

Page 21: ...rical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform...

Page 22: ...ack into place to renew seal integrity Installation Instructions PM2RM SURFACE MOUNT 10W Driver Housing 10 Make sure UPM housing gasket is free of any dirt or debris Attach the faceplate by tightening...

Page 23: ...Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of t...

Page 24: ...READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Ground Hot Neutral Installation Instructions PM2DRM TREE STRAP 10W Dual Driver Housing Red FIXTURE Hydrolock Plate Black D Driver White B...

Page 25: ...ical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform...

Page 26: ...orientation of UPM Take note of mounting plate holes indicated with arrows on the universal ring holes to mount UPM in correct orientation Installation Instructions PM2DRM ROUND CAMLOCK 10W Dual Drive...

Page 27: ...al Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform al...

Page 28: ...hed orientation as shown Figure A 5 Rotate housing 90 counter clockwise Figure B Tighten set screw with 5 64 Allen wrench on outside of UPM housing to lock in place Figure C Installation Instructions...

Page 29: ...ode Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all se...

Page 30: ...PM is designed as an installation aid and NOT a safety cable Do not add weight to or drop faceplate Red FIXTURE Hydrolock Plate Black Driver White Black Green Black White Hydrolock Plate Green Driver...

Reviews: