4.  Attach the UPM housing at mounting brackets 

with ¼” fasteners (By Others). Use suitable 

mounting hardware for surface.

 NOTE: Many methods exist to bolt to a 

flat surface. The fixture is provided with 

mounting brackets with ¼” holes. 

5.  Connect 1/2” conduit connector through 

female threaded conduit entry.

 

NOTE: Surface conduit is a common entrance 

for water if not properly sealed. Seal 

connector threads and conduit with a suitable 

sealant  (Teflon tape, adhesive, etc.). Sealing 

the conduit after knockouts are removed is 

required to maintain warranty.

6.  Pull branch circuit wiring necessary for 

installation (By Others.)

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

1.  Prepare in final mounting position according to 

designed lighting plan. 

2.  Drill holes into surface for ¼” fasteners (By 

Others)  on locations required

.

3.  Remove Patented Knockout(s) as necessary 

from the inside of the UPM housing for branch 

circuit wiring and lamp leads to remote mounted 

fixture. Leave remaining unused knockouts in 

place to maintain seal.

 NOTE: Patented design featuring a silicone ‘O’ 

Ring allowing knockout to be tapped back into 

place to renew seal integrity.

Installation Instructions

PM2DRM SURFACE MOUNT™

10W Dual Driver Housing

7.  Attach tether wire under screw head at the 

base of the UPM housing and tighten. Slowly 

lower the faceplate until tether is taut. 

NOTE: Faceplate tether supplied with UPM 

is designed as an installation aid and NOT a 

safety cable. Do not add weight to, or drop 

faceplate.

LINE

Red

FIXTURE

COM

Hydrolock

Plate

Black

GROUND

Driver

White
Black
Green

DIM +
DIM -

Black
White

Hydrolock

Plate

Green

Driver

White
Black
White
Blue
Green

LINE

COM

GROUND

Orange
Orange
Brown
Blue

Black
Gray

FIXTURE

FIXTURE

Green

Green

LINE

Red

FIXTURE

COM

Driver

Black

GROUND

DIM +
DIM -

GROUND IN HOUSING

LINE

Red

FIXTURE

COM

Driver

Black

DIM +
DIM -

GROUND ON PLATE

LINE

Red

FIXTURE

COM

Driver

Black

DIM +
DIM -

HP2RM

HP2 TR

TMB

PCIII

Generic TR

GROUND IN HOUSING

LINE

Quick

Connect

COM

Driver

FIXTURE

DIM +
DIM -

PM3

GROUND IN HOUSING

LINE

Quick

Connect

COM

Driver

FIXTURE

DIM +
DIM -

Quick

Connect

Driver

FIXTURE

DIM +
DIM -

PM3D

GROUND IN HOUSING

LINE

COM

Remote

Driver

DIM +
DIM -

Fixture
Fixture

GROUND ON PLATE

LINE

COM

Driver

DIM +
DIM -

PCIII

Quick

Connect

FIXTURE

LINE

Red

FIXTURE

COM

Remote

Driver

Black

DIM +
DIM -

MA/AP

GROUND

GROUND IN HOUSING

LINE

COM

Remote

Driver

DIM +
DIM -

DIM +
DIM -

Fixture

Fixture

Remote

Driver

Fixture

Fixture

LINE

COM

Remote

Driver

GROUND

F
Fixture -

GROUND IN HOUSING

LINE

COM

Remote

Driver

F
Fixture -

Remote

Driver

F
Fixture -

GROUND IN HOUSING

LINE

COM

Remote

Driver

F
Fixture -

WIRING DIAGRAM - 010 Control Type

9.  Use waterproof wire connectors (By Others) to 

connect driver primary leads to branch circuit 

wires. Connect incoming ground to ground wire 

provided in UPM housing. Connect incoming 

dimming control wires to driver dimming 

controls. Connect secondary leads to fixture 

leads. 

See wiring diagram.

LINE

Red

FIXTURE

COM

Hydrolock

Plate

Black

GROUND

Driver

White
Black
Green

DIM +
DIM -

Black
White

Hydrolock

Plate

Green

Driver

White
Black
White
Blue
Green

LINE

COM

GROUND

Orange
Orange
Brown
Blue

Black
Gray

FIXTURE

FIXTURE

Green

Green

LINE

Red

FIXTURE

COM

Driver

Black

GROUND

DIM +
DIM -

GROUND IN HOUSING

LINE

Red

FIXTURE

COM

Driver

Black

DIM +
DIM -

GROUND ON PLATE

LINE

Red

FIXTURE

COM

Driver

Black

DIM +
DIM -

HP2RM

HP2 TR

TMB

PCIII

Generic TR

GROUND IN HOUSING

LINE

Quick

Connect

COM

Driver

FIXTURE

DIM +
DIM -

PM3

GROUND IN HOUSING

LINE

Quick

Connect

COM

Driver

FIXTURE

DIM +
DIM -

Quick

Connect

Driver

FIXTURE

DIM +
DIM -

PM3D

GROUND IN HOUSING

LINE

COM

Remote

Driver

DIM +
DIM -

Fixture
Fixture

GROUND ON PLATE

LINE

COM

Driver

DIM +
DIM -

PCIII

Quick

Connect

FIXTURE

LINE

Red

FIXTURE

COM

Remote

Driver

Black

DIM +
DIM -

MA/AP

GROUND

GROUND IN HOUSING

LINE

COM

Remote

Driver

DIM +
DIM -

DIM +
DIM -

Fixture

Fixture

Remote

Driver

Fixture

Fixture

LINE

COM

Remote

Driver

GROUND

F
Fixture -

GROUND IN HOUSING

LINE

COM

Remote

Driver

F
Fixture -

Remote

Driver

F
Fixture -

GROUND IN HOUSING

LINE

COM

Remote

Driver

F
Fixture -

WIRING DIAGRAM - INC Control Type

8.  Use waterproof wire connectors (By Others) to 

connect driver primary leads to branch circuit 

wires. Connect incoming ground to ground wire 

provided in UPM housing. Connect secondary 

leads to fixture leads. 

See wiring diagram.

Ground

Hot

Neutral

10.  Make sure UPM body gasket is free of any dirt or 

debris. Attach the faceplate by tightening the 

(4) #6-32 captive screws evenly  using a 5/64” 

Allen wrench. 

Summary of Contents for SARATOGA Series

Page 1: ...RM DRM Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code Canadian Electrical Code and all Local and Provi...

Page 2: ...rtight connections from remote driver to fixture leads using waterproof wire connectors By Others in splice location as per NEC Fixture Installation SARATOGA SERIES Remote Solid State LED Standard Ins...

Page 3: ...pull out end cap assembly LED is still attached to leads Detach heatsink from fixture body via quick disconnect Twist and gently pull away optic from optic holder Do not pull on connector or wiring H...

Page 4: ...refully pull out end cap assembly LED is still attached to leads Detach heatsink from fixture body via quick disconnect Loosen then remove two 2 8 32 screws from optic holder using 5 64 Allen wrench D...

Page 5: ...ome extremely hot Do not touch hot lens or fixture body Do not touch the lamp at any time Use a clean dry soft cloth to handle the lamp Oil from skin may damage the lamp and cause it to rupture Replac...

Page 6: ...ian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing o...

Page 7: ...wiring necessary for installation By Others Single Remote Driver 7 Connect branch circuit to terminal block Connect incoming ground to ground wire provided on NEMA 3R housing Connect secondary leads t...

Page 8: ...alant Teflon tape adhesive etc Sealing the conduit after knockouts are removed is required to maintain warranty 8 Re attach cover Tighten cover screw 5 Pull branch circuit wiring necessary for install...

Page 9: ...ck Connect incoming ground to ground wire provided on NEMA 3R housing Connect secondary lamp leads to terminal block See labels on terminal block for additional information 4 Connect conduit connector...

Page 10: ...nd wire provided on NEMA 3R housing Connect secondary lamp leads to terminal A See labels on terminal block for additional information 4 Connect conduit connector through female threaded conduit entry...

Page 11: ...an Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of...

Page 12: ...crews on Stability Flange to secure housing to EMT Remove excess EMT as needed 7 Per DIG IT Guide backfill the gap between the bottom of housing and bottom of hole with sand for drainage Housing Insta...

Page 13: ...e watertight connections using waterproof wire connectors provided to leads on the bottom of Patented HydroLock Barrier Plate Assembly See wiring diagram s 5 Turn HydroLock Barrier Plate clockwise to...

Page 14: ...EVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS 10 Remove any dirt or debris in O ring groove near top of housing Place O Ring inside of groove Failure to clean groove of debris w...

Page 15: ...n Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of...

Page 16: ...back of the UPM housing Feed safety cable through opposing ends of the connector Pull on wires to assure the connection is secure Leave enough slack in safety cable for tree growth Adjustments can be...

Page 17: ...ce with the National Electrical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protect...

Page 18: ...n 2 Pullbranchcircuitwiringnecessaryforinstallation By Others 3 Install universal mounting ring IMPORTANT Orientation of universal ring will affect orientation of UPM Take note of mounting plate holes...

Page 19: ...anadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servici...

Page 20: ...with 5 64 Allen wrench on outside of UPM housing to lock in place Figure C IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Installation In...

Page 21: ...rical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform...

Page 22: ...ack into place to renew seal integrity Installation Instructions PM2RM SURFACE MOUNT 10W Driver Housing 10 Make sure UPM housing gasket is free of any dirt or debris Attach the faceplate by tightening...

Page 23: ...Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of t...

Page 24: ...READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Ground Hot Neutral Installation Instructions PM2DRM TREE STRAP 10W Dual Driver Housing Red FIXTURE Hydrolock Plate Black D Driver White B...

Page 25: ...ical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform...

Page 26: ...orientation of UPM Take note of mounting plate holes indicated with arrows on the universal ring holes to mount UPM in correct orientation Installation Instructions PM2DRM ROUND CAMLOCK 10W Dual Drive...

Page 27: ...al Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform al...

Page 28: ...hed orientation as shown Figure A 5 Rotate housing 90 counter clockwise Figure B Tighten set screw with 5 64 Allen wrench on outside of UPM housing to lock in place Figure C Installation Instructions...

Page 29: ...ode Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all se...

Page 30: ...PM is designed as an installation aid and NOT a safety cable Do not add weight to or drop faceplate Red FIXTURE Hydrolock Plate Black Driver White Black Green Black White Hydrolock Plate Green Driver...

Reviews: