AXIS Q1656 Box Camera Series
Specifications
•
Audio out
– 3.5 mm output for audio (line level) that can be connected to a public address (PA) system or an active
speaker with a built-in amplifier. A stereo connector must be used for audio out.
Audio input
1 Tip
2 Ring
3 Sleeve
Unbalanced microphone (with or without electret
power) or line
Electret power if selected
Ground
Balanced microphone (with or without phantom power)
or line, “hot” signal
Balanced microphone (with or without phantom
power) or line, “cold” signal
Ground
Digital signal
Ring power if selected
Ground
Audio output
1 Tip
2 Ring
3 Sleeve
Channel 1, unbalanced line, mono
Channel 1, unbalanced line, mono
Ground
I/O connector
Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm
notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:
Digital input -
For connecting devices that can toggle between an open and closed circuit, for example PIR sensors, door/window
contacts, and glass break detectors.
Supervised input -
Enables possibility to detect tampering on a digital input.
Digital output -
For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX®
Application Programming Interface, through an event or from the product’s webpage.
6-pin terminal block
Function
Pin
Notes
Specifications
DC ground
1
0 V DC
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
12 V DC
Max load = 50 mA