Feeding-in a redundant input signal (function on request)
The AXING MIP-headend series can be fed from an additional redundant input signal source. Switching can be be triggered
through various selectable criteria (input level, bit error rate etc.).
In the example the DiSEqC command is used to switch from the main antenna to the redundant backup antenna. Both satellite
antennas must be aligned to the same satellite reception position.
The backup antenna should be located far away from the main antenna. A fiber-connection is suitable to bridge the distance
between the two antennas. In bad weather conditions at the main antenna, the system can switch to the backup antenna to
ensure seamless reception.
1.4.
Output transport stream
As output transport stream 512 SPTS or 8 MPTS (MIP 8-0x) or 16 MPTS (MIP 16-0x) can be choosen.
SPTS
: each program is attached to one transport stream.
MPTS
: multiple programs are attached to a transport stream, using
remux or crossmultiplex mode.
1.5.
Graphical user interface
The settings can be changed via the user interface of the integrated web interface. To access the user interface and thus
configure the devices, you need a standard PC/laptop with a network interface and the actual version of the installed web
browser.
The configuration interface is "mobile ready" and can therefore also be used from the smartphone or tablet.