| 66
3.0
Integer
R/W
Output Mode:
0: Stereo
1: Mono (Left)
2: Mono (Right)
3: Mono (Left + Right)
4.0
Integer
R/W
Output Rate:
0: 32 kHz
1: 44.1 kHz
2: 48 kHz
3: 64 kHz
4: 88.2 kHz
5: 96 kHz
6: External Sync
7: Auto 32 kHz
8: Auto 44.1 kHz
9: Auto 48 kHz
10: Auto 64 kHz
11: Auto 88.2 kHz
12: Auto 96 kHz
5.0
Integer
R/W
Output Resolution:
0: 16 bit
1: 20 bit
2: 24 bit
6.0
Integer
R/W
Output Generator:
0: OFF
1: Left and Right
2: Left Only
3: Right Only
7.0
Integer
R/W
Accept External Command:
0: OFF
1: ON
8.0
Integer
R/W
Output Source:
0: Input A - Manual
1: Input B - Manual
2: Input C - Manual
3: Input D - Manual
4: Automatic
5: OFF
dynamicData
.1.3.6.1.4.1.27295.4.1.4
OID
Type
Access Description
1.0
Octet string
R
All Dynamic Data:
see appendix A for OID structure data.
2.0
Integer
R
Input A: Left Input Level:
from 0 (-40.0dBu) to 240 (+20.0dBu) step 0.25dBu
3.0
Integer
R
Input A: Right Input Level:
from 0 (-40.0dBu) to 240 (+20.0dBu) step 0.25dBu
4.0
Integer
R
Input B: Left Input Level:
from 0 (-40.0dBu) to 240 (+20.0dBu) step 0.25dBu
5.0
Integer
R
Input B: Right Input Level:
from 0 (-40.0dBu) to 240 (+20.0dBu) step 0.25dBu
6.0
Integer
R
Input C: Left Input Level:
from 0 (-60.0dBFS) to 240 (+0.0dBFS) step 0.25dBFS
7.0
Integer
R
Input C: Right Input Level:
from 0 (-60.0dBFS) to 240 (+0.0dBFS) step 0.25dBFS