PAGE 56
W i n d o w s P C S o f t w a r e
–
I/O Port
: Currently not in use (Audio).
–
Ethernet MAC 1
: The initialization of the ethernet module 1 has failed.
–
Ethernet MAC 2
: The initialization of the ethernet module 2 has failed.
–
Slot 1 Access
: The communication with the E1 interface 1 is faulty.
–
Slot 2 Access
: The communication with the E1 interface 2is faulty.
• Under
Application alarms
all possible application alarms are displayed.
A red LED signals a currently existing alarm. It is also displayed how often
the alarm occurs since the unit has been switched on. You can reset the
alarm counter by pressing the
Alarm Counter Reset
button .
–
Input 1
: No input signal available
• The current system temperature can be found under
System Tempera-
ture
. The temperature is measured in °C. A normal system temperature
lies around 30...45°C.
• The current DSP load is displayed under
DSP Load
.
• Under
Ethernet status
you can find information about the connection sta-
tus of the
LAN 1
and
LAN 2
interfaces.
• Under
Abs. data rates
the absolute data rates of your ethernet connec-
tions are displayed. TX stands for transmit direction and RX for receive di-
rection.
TIP
You can also configure a system alarm as relay output (see PAGE 40).
Summary of Contents for MAGIC EEC
Page 1: ...MAGIC EEC ETI EDI Converter Hardware Software Manual ...
Page 2: ... ...
Page 4: ......
Page 6: ... ...
Page 10: ......
Page 16: ...PAGE 16 ...
Page 18: ...PAGE 18 S y s t e m d e s c r i p t i o n ...
Page 22: ...PAGE 22 P u t t i n g M A G I C E E C i n t o o p e r a t i o n ...
Page 62: ...PAGE 62 M e n u S t r u c t u r e A1 1 Menu ...
Page 68: ...PAGE 68 I n t e r f a c e s ...
Page 72: ...PAGE 72 T e c h n i c a l D a t a ...
Page 74: ...PAGE 74 S e r v i c e I n f o r m a t i o n ...
Page 79: ...PAGE 79 I n d e x Version 58 Voltage changes 40 W Warranty 19 Y yellow 25 ...
Page 80: ...PAGE 80 I n d e x ...
Page 82: ......