background image

www.avidsen.com

V1

OPTION

BATTERIE DE SECOURS

OPTION COMPATIBLE

SMARTPHONE

24V

L

1,75M

PAR BATTANT

150KG

PAR BATTANT

KG

COMPATIBLE TOUS

TYPES DE PORTAILS

PORTAIL

À BATTANT

24V

150 KG PER PANEL

SWING GATES

COMPATIBLE WITH ALL 

TYPES OF OPENWORK 

GATES

1.75 M PER 

PANEL

BACKUP BATTERY

OPTION

COMPATIBLE WITH 

AVIDSEN HOME

TECHNICAL

SUPPORT

WARRANTY

3

YEARS

CONNECTED MOTOR 

DRIVE KIT

EN

TEHA CONNECT

With actuators – For two-panel swing gates

Ref. 114174

Summary of Contents for 114174

Page 1: ...MPATIBLE TOUS TYPES DE PORTAILS PORTAIL BATTANT 24V 150 KG PER PANEL SWING GATES COMPATIBLE WITH ALL TYPES OF OPENWORK GATES 1 75 M PER PANEL BACKUP BATTERY OPTION COMPATIBLE WITH AVIDSEN HOME TECHNIC...

Page 2: ...eGate connected module 21 6 7 Backup battery optional ref 580293 22 6 8 solar power kit 22 D BEGINNING OPERATION 1 SETTINGS INTERFACE 23 2 QUICK SETTINGS 23 2 1 Self learning 23 2 2 Adding remote cont...

Page 3: ...E 39 5 1 If you have an Android smartphone with Google Assistant 40 6 USING THE PRODUCT WITH AMAZON ALEXA 40 7 SCENARIO AND AUTOMATION 41 7 1 Scenario 41 7 2 Creating an automation 42 7 2 1 Programmin...

Page 4: ...e gate s movement Do not manually activate the gate when the motor drive is not disengaged from the gate Avidsen cannot be held liable for any use that does not comply with the instructions in this ma...

Page 5: ...s containing harmful substances are marked with symbols shown opposite which indicate that it is forbidden to discard them in the household waste The corresponding heavy metals are referred to as foll...

Page 6: ...ator 2 Switchgear 3 Flashing light 4 Remote control 5 Photocells 6 Gate mounting bracket 7 Post mounting bracket Attachment of the brackets on the posts Attachment of the switchgear on the post 12 8 6...

Page 7: ...s automatic closing The flashing light is an essential safety component The photocell type safety devices and their correct operation must be checked every six months SPECIFICATIONS OF THE GATE TO MO...

Page 8: ...follows Subpanels Following installation there may be a shear zone between the panel and the corner of the post In this case it is recommended to remove this zone leaving a minimum working distance o...

Page 9: ...s of the gate do not hang above a footpath or public access road 2 INSTALLING ACTUATORS The motor drive must be installed by qualified personnel in compliance with all the indications provided in the...

Page 10: ...osts must be cut so that D is equal to 170mm D post If D 0mm place a shim thick enough so that D is equal to 0mm D post Determine the opening angle of each panel based on the data in the following tab...

Page 11: ...ount them as low as possible for aesthetic and technical reasons CORRECT IDEAL The instructions below describe installation of the left actuator to install the right actuator repeat the process while...

Page 12: ...be significant force on the mounting bracket when the motor drive is running We recommend sealing threaded rods at least 15 cm in length If the post is made of metal we recommend welding or passing th...

Page 13: ...arriage to the end of the actuator then back 0 5 to 1 cm inwards STEP 2 Close the gate by pressing it securely against its central stop then rotate the actuator in order to install the base of the gat...

Page 14: ...actuator cables must not exceed 8 m per actuator Therefore the switchgear must be mounted less than 6 m from each actuator Use two screws to install and mount the switchgear in the defined location S...

Page 15: ...ent part of the flashing light by unscrewing the 2 screws that hold the upper part of the flashing light Continuing to use a screwdriver remove the flashing light bracket by unscrewing the 2 screws in...

Page 16: ...the infrared beam of the photocells Place the photocells at exactly the same height from the ground they must be perfectly aligned and parallel to each other The distance between the outer side of the...

Page 17: ...control box The photocells must be installed on the inner side of the property The distance between the main edges of the gate in an open position at 90 and the photocells must be between 10cm and 15...

Page 18: ...cure the cable to prevent it from being torn off Never drill into the electronic box whether to pass the cable or attach it to the post This would compromise the seal and void the warranty Remove the...

Page 19: ...inwards 352 2 7 75 16 1 1 3 2 9 0 0 0 0 ZDUQ ZDUQ actuator installed on the panel that opens first red red black black 6 3 FLASHING LIGHT Connect the flashing light wires to the terminal block as sho...

Page 20: ...e terminal block as shown in the diagram below and then reconnect the terminal block 1 set of photocells BAT TRANS GND GND PHO 24V M1 M2 M1 M2 warn warn 2B NO COM NC Photocell RX1 Photocell TX1 2 sets...

Page 21: ...BAT TRANS GND GND PHO 24V M1 M2 M1 M2 warn warn 2B AC IN 230V AC L N Install the magnet enabling gate state feedback from the app Put the gate in closed position Install the pre wired magnet on the pa...

Page 22: ...off safety switch in the OFF position After this test reconnect the power supply safety switch to the ON position The battery will take over if the power is cut 6 8 SOLAR POWER KIT Please note that wh...

Page 23: ...e sure of being on MENU 0 of the display press on PROG 2 or 3 times and the green LED should be switched on only the green LED When the user performs no action on a button for 15 seconds the system au...

Page 24: ...less than 3s reduce the speed L1 L2 L3 L4 In phase 1 panel M1 did not reach a stop after opening for 60s or cable section too weak L1 L2 L3 L4 In phase 1 panel M2 did not reach a stop after opening f...

Page 25: ...ready been memorised you can memorise other remote controls copy function For each new remote control to be memorised follow the procedure below Stand near the motor Press simultaneously on both butto...

Page 26: ...art a new self learning procedure simple rules MODE TIME DELAY FORCE SPEED simple rules Acceleration Photocell mode Type of gate Stop tolerance simple rules Closing time interval Pre flashing time PRO...

Page 27: ...no auto closing MODE 2 auto closing MODE 3 collective mode motor force operating mode time delay 0 15 secs 1 30 secs by default 2 45 secs 3 60 secs 4 90 secs PROG 3s PROG L1 L2 L3 L4 L1 L2 L3 L4 L1 L2...

Page 28: ...djustable time see Time delay then closes automatically Unlike the automatic closure mode If you press a command during opening it will not be acknowledged If you press a command during the time delay...

Page 29: ...force follow the procedure below Press PROG for 3 seconds L0 will flash once and L1 will turn on Press twice and L3 will switch on instead of L1 Press OK and the number of LEDs that turn on will indic...

Page 30: ...seconds L0 will flash twice Press OK and the number of LEDs that turn on will indicate the set value Use the and buttons to change this value Press OK to confirm this value All the LEDs will turn on a...

Page 31: ...r strain the system considers it to be pushing against an obstacle If the panel comes under strain when less than such percentage remains to be completed the system considers that the panel has reache...

Page 32: ...imes Press OK The number of LEDs that turn on will indicate the set value Use the and buttons to change this value see table below Press OK to confirm this value All the LEDs will turn on and off to c...

Page 33: ...e setting the gate into motion ensure that there is no person in the area in which the gate moves children vehicles etc In the event of a malfunction remove the actuators from the gate mounting bracke...

Page 34: ...and If you activate the gate command during the time delay it is reloaded with the initial time to extend the time before automatic closure If you activate the gate command during closure the gate wil...

Page 35: ...e may be set in motion by the wind or an external push It is therefore im portant to be careful or block the gate to avoid any risk of injury Just remove the pin and raise the operator arm The gate ca...

Page 36: ...me app from the Android Play Store or Apple App Store Launch the app and log in if you already have an account If not press CREATE A NEW ACCOUNT and let the app guide you After accepting the privacy p...

Page 37: ...air and select Home Gate Make sure the contactor is connected and its indicator light is flashing If not press and hold the reset button for 5s so that the indicator starts flashing Select your 2 4 GH...

Page 38: ...motor error etc if the gate remains ajar the contactor cannot be held responsible IMPORTANT The dry contact signal is the same whether the opening or closing of the gate is triggered The contactor wi...

Page 39: ...LE HOME NOTE the name you give your Avidsen Home devices is the one that will be recognised by Google Assistant Example if you have a contactor named gate OK Google open gate will work whereas OK Goog...

Page 40: ...es to the Alexa app or your operating system The Amazon Alexa Assistant can help you control your connected devices For example you can use the following commands Alexa Open gate Alexa Close gate Alex...

Page 41: ...m in the Avidsen Home app allows you to group actions that will be triggered on demand by clicking on a single button on your smartphone Example creating an I m going scenario to turn off my smart plu...

Page 42: ...te is in closed position The automation system in the Avidsen Home app allows you to group devices and actions which will be triggered automatically by the action of another device or a condition temp...

Page 43: ...ing the condition type choose the conditions themselves 1 3 5 7 2 4 6 1 Set a temperature weather condition 2 Set a humidity weather condition 3 Set a weather condition 4 Set a sunrise or sunset condi...

Page 44: ...corded in the app The last setting allows you to define a time slot during the day if necessary during which to authorise the automation launch Once all these settings have been confirmed you can save...

Page 45: ...column The time configured will appear between the two parallel lines You can ask for a repeat of the scenario on different days of the week To configure this click on Repeat The conditions have been...

Page 46: ...ience in our example OUVERTURE PORTAIL GATE OPENING Once all parameters have been set click on Save If you wish to access the details or delete it click on the icon at the top right of its name E USE...

Page 47: ...EN 47 Backup battery Photocells Additional remote controls Gate video intercom system Connected module Coded keypad Solar kit 8 OPTIONAL ACCESSORIES E USE CONNECTED MOTOR DRIVE KIT WITH ACTUATORS...

Page 48: ...nce of the mechanical parts every 12 months tightening screws lubrication checking the hinges stops and gate balance etc maintenance of the electronic parts every 6 months motor operation photocells c...

Page 49: ...opening I L1 L2 L3 L4 Motor M1 is not connected or incorrectly connected contact failure Check connections E L1 L2 L3 L4 Motor M2 is not connected or incorrectly connected contact failure Check connec...

Page 50: ...l device is connected to input 2B LED L2 turns on when the contactor of the component is activated 2 3 TOTAL RESET You can reset to factory settings To do so press and and OK at the same time and hold...

Page 51: ...wallowed immediately contact a doctor or go to A E Never short circuit the batteries and do not burn or recharge them as they may explode This logo denotes that devices no longer in use should not be...

Page 52: ...cycles day 50 Operating temperature 20 C 60 C Protection rating IP44 ELECTRONIC CONTROL BOX Type Electronic control box for 2 x 24 VDC actuators Contents 1 AVLO electronic card 1 x 230 20 VAC transfor...

Page 53: ...ection rating IP44 REMOTE CONTROL Type Type OOK AM modulation 16 bit Rolling code encoder i e 65 536 possible combinations Frequency 433 92MHz Power supply 3V via CR2032 battery Keys 4 keys Radiated p...

Page 54: ...the fumes are also hazardous to your health and are explosive Do not use any tool that can conduct voltage wire brush sharp tool etc for cleaning The receipt or invoice is proof of purchase date 3 HEL...

Page 55: ...ssed pursuant to the applicable standards in force Directive RED 2014 53 EU EN 300220 1 V3 1 1 EN 300220 2 V3 1 1 Directive LVD 2014 35 EU EN 62479 2010 EN 62368 1 2014 A11 2017 Directive EMC 2014 30...

Page 56: ...Avidsen 19 avenue Marcel Dassault ZAC des Deux Lions 37200 Tours France...

Reviews: