EN
28
D - BEGINNING OPERATION
3.1.1. OPERATING MODE (AUTOMATIC
CLOSING OR SEMI-AUTOMATIC
CLOSING)
This automatic gate opening mechanism has 3
operating modes.
Semi-automatic mode (mode 1, LED 1 on)
(default)
• Closed gate -> one press on the gate command
(complete or partial) opens the gate.
• Open gate -> one press on the gate command
(complete or partial) closes the gate.
While the gate is in motion, you can stop it by
pressing the (gate or pedestrian) command.
By pressing on the gate command again, the gate
swings in the opposite direction.
Automatic closing mode (mode 2, LED 1 and
2 on)
In this operating mode, you must connect the
photocells and they must be functional.
• Closed gate -> one press on the gate command
(complete or partial opening) opens the
gate, which remains open for a certain time
(adjustable time, see “Time delay”), then closes
automatically.
•
During the time delay, you can cancel the
automatic closure by pressing a command
(complete or partial). The gate stays open and
you must press the command to close the gate.
• While the gate is in motion, you can stop it by
pressing a command (complete or partial).
• By pressing on a command again, the gate
starts in the opposite direction.
Collective mode (mode 3, LED 1, 2 and 3 on)
This mode is used for a gate with collective
access. In this operating mode, you must connect
the photocells and they must be functional.
• Closed gate -> one press on the gate command
opens the gate, which remains open for a
certain time (adjustable time, see “Time delay”),
then closes automatically.
Unlike the automatic closure mode:
• If you press a command during opening, it will
not be acknowledged.
• If you press a command during the time delay,
instead of cancelling the automatic closure, the
time delay starts again at 0.
• If you press a command during closure, the gate
stops, opens back up and starts the automatic
closure time delay.
Note: you can only control complete opening;
the partial opening command does not work.
To choose the operating mode, follow this
procedure:
• Press on
PROG
2 or 3 times and the green LED
should be switched on (only the green LED)
• Press “
PROG
” for 3 seconds. L0 will flash once
and L1 will turn on.
• Press
OK
and the number of LEDs switched on
will then indicate the previously set operating
mode (mode 1 by default).
• To change the operating mode, use the “+” and
“-” buttons, then confirm with the
OK
button.
N.B.: applicable regulations require the
installation of photocells for safety during
automatic closing.
3.1.2. TIME DELAY (FOR AUTOMATIC MODE)
The time delay is the time during which the gate
remains open before closing automatically (if
automatic closing is activated).
To adjust this value, follow this procedure:
• Press on
PROG
2 or 3 times and the green LED
should be switched on (only the green LED)
• Press “
PROG
” for 3 seconds. L0 will flash once
and L1 will turn on.
• Press “+” once. L2 will turn on instead of L1.
• Press “
OK
”. The number of LEDs that turn on
will indicate the set value.
• Use the “+” and “-” buttons to change this value
(see table below).
• Press “
OK
” to confirm this value. All the LEDs
will turn on and off to confirm the operation.
CONNECTED MOTOR DRIVE KIT WITH ACTUATORS