D - BEGINNING OPERATION
To diagnose any problems, here is the list of codes
and their meaning:
: LED
off
: LED
on
:
Flashing
LED
There are two types of code: Error (
E
) or
Information (
I
). N.B. an error requires action from
the installer to correct the motor drive problem.
LED
Description
L1 L2 L3 L4
In phase 0, panel M1
did not arrive at a stop
after closing for 60s,
disengagement or cable
section too weak?
L1 L2 L3 L4
In phase 0, panel M2
did not arrive at a stop
after closing for 60s,
disengagement or cable
section too weak?
L1 L2 L3 L4
In phase 0, motor M1
was not detected (not /
incorrectly connected?).
L1 L2 L3 L4
In phase 0, motor M2
was not detected (not /
incorrectly connected?).
L1 L2 L3 L4
In phase 1, motor M1
reached the stop after
opening for less than 3s:
reduce the speed.
L1 L2 L3 L4
In phase 1, motor M2
reached the stop after
opening for less than 3s:
reduce the speed.
L1 L2 L3 L4
In phase 1, panel M1 did
not reach a stop after
opening for 60s or cable
section too weak?
L1 L2 L3 L4
In phase 1, panel M2 did
not reach a stop after
opening for 60s or cable
section too weak?
L1 L2 L3 L4
In phase 1, motor M1 was
not detected (contact
failure, electronic card
problem?).
Review motor
connections.
L1 L2 L3 L4
In phase 1, motor M2 was
not detected (contact
failure, electronic card
problem?).
Review motor
connections.
L1 L2 L3 L4
In phase 1 (opening),
M1 is not recognised.
Note
1
.
L1 L2 L3 L4
In phase 1 (opening),
M2 is not recognised.
Note
1
.
L1 L2 L3 L4
In phase 2 (closing),
M1 is not recognised.
Note
2
.
L1 L2 L3 L4
In phase 2 (closing),
M2 is not recognised.
Note 2
.
L1 L2 L3 L4
Self-learning was
interrupted by the user.
2.2. ADDING REMOTE CONTROLS
You can control the complete or partial (pedestrian)
opening of the gate. On a remote control, it is
possible to decide which button will be used as the
gate command and which button will be used as
the pedestrian command.
CONNECTED MOTOR DRIVE KIT WITH ACTUATORS