C - INSTALLATION
6 - CONNECTIONS
•
The cable run between must comply with applicable standards (NFC 15-100).
•
Either the cable is 80 cm deep with red warning mesh, or the cable is run through a sheath.
vers
230V
Safety instructions
- All electrical connections must be performed with the power switched off (safety switch in OFF position).
- These connections must be made by a qualified electrician.
- It is imperative and mandatory to use the cable gland provided to pass and attach the 230V power cable
in the switchgear. Once the cable has passed through the cable gland, tighten the outer nut to secure the
cable to prevent it from being torn off.
Never drill into the electronic box (whether to pass the cable or attach it to the post). This would compromise
the seal and void the warranty.
•
Remove the protective cover from the transformer.
6.1 - THE MAINS ELECTRICITY
Important notes:
• The electrical line must solely be used to power the gate motor drive and be protected by a fuse or circuit
breaker (6 A min, 16 A max) and a differential device (30 mA). It must be compliant with the applicable
electrical safety standards.
- The 230 V power cable must be HO5RN-F type.
• Connect the wires from the power supply and make sure they are properly secured in the terminal block.
Once the 230V cable has been run through the cable duct, replace the protective cover.
CONNECTED MOTOR DRIVE KIT WITH ACTUATORS