31
2.13 Connecting the Sensor/Relay device to NV6000 (EXP)/7000H/9000E I/O
card
The I/O Audio card enables you to connect (4) sensor inputs and (4) relay outputs. Just
connect the external sensor and relay pin directly to the NV6000/7000H I/O card pinhole.
Check the table below and locate which pinhole is assigned to sensor input and relay output.
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
2.13.1
I/O Card Sensor and Relay pinhole allocation:
The signal from the sensor (i.e., infrared sensors, smoke detectors, proximity sensors, door
sensors, etc.) is being transmitted to the I/O card and this triggers the system to respond and
send signal to relay device (i.e., alarm, telephone etc).
Pin #
Definition
Pin #
Definition
1
Sensor input signal 1+
11
Relay Normal Close 1
2
Sensor output signal 1-(GND)
12
Relay Common 2
3
Sensor input signal 2+
13
Relay Normal Open 2
4
Sensor output signal 2-(GND)
14
Relay Normal Close 2
5
Sensor input signal 3+
15
Relay Common 3
6
Sensor output signal 3-(GND)
16
Relay Normal Open 3
7
Sensor input signal 4+
17
Relay Normal Close 3
8
Sensor output signal 4-(GND)
18
Relay Common 4
9
Relay Common 1
19
Relay Normal Open 4
10
Relay Normal Open 1
20
Relay Normal Close 4
2.14 The Sensor input and Relay output Specifications
You may use the sensor input and relay output specifications table below for your reference.
A. Sensor
Input
Specification
Absolute Maximum Ratings
(Ta=25°C)
Parameter Symbol
Rating
Unit
Forward Current
I
F
50 mA
Reverse Voltage
V
R
6 V
Input
Power Dissipation
P
70
mW
Electrical/Optical Characteristics
(Ta=25°C)
Parameter Symbol
Min
Typ.
Max.
Unit
Conditions
Forward Current
V
F
- 1.2
1.4 V
I
F
=20mA
Reverse Voltage
I
R
- - 10 A
V
R
=4V
Input
Terminal Capacitance
C
t
- 30
250
pF
V=o,
f=1KHz
Parameter Symbol
Min
Typ.
Max.
Unit
Conditions
t
p
Collector Dark Current
I
CEO
- - 100 nA
V
CE