41
G
USE
LOCATION
Place the magnet (provided with the device) on the door or the win-
dow to protect while the AF913R detector must be placed on the
frame. If you want, you can select the function of end of alarm by
means of micro-switch 3:
ON = end of alarm enabled
OFF = end of alarm desabled.
The anti-shock protection can be connected by means of micro-
switch 4:
ON = anti-shock connected
OFF = anti-shock disconnected.
Adjust then the pulse count as indicated in fig. 4 to produce a shock
alarm after the chosen number of impulses.
Enable the NC input by removing JP2. Connect the output contact
(usually an NC contact) of a vibrating inertial detector or a cord
detector for roller shutter protection to the NC input of the AF913R
detector’s terminal board. Adjust the pulse count as indicated in fig.
4 to produce an alarm after the chosen number of pulses.
Connect the output contact of a detector for technical alarms to the
terminal board.
We suggest using the NO input which cuts out the pulse count auto-
matically.
Protection of
doors and windows
Protection of roller
shutters, walls
(external connection of
inertial or cord detectors)
Technical alarms
(external connection
of detectors
for technical alarms)