29
G
In this case, the device can be used to connect and disconnect a wired con-
trol panel equipped with a special input by using the contact of relay B.
By programming the AF939R remote control, the operations shown in the
tab. below will be carried out.
Status of
Action
LEDs and
1 st
Press
Press
contacts
supply
red push-button
green push-button
Contact
open
N° 3 closing impulse, N° 1 closing impulse,
relay A
then it opens
then it opens
Contact
closed
open
closed
relay B
(system on)
(system off)
L1 Red
off
on
off
L2 Yellow
off
off
off
L3 Green
on
on
on
C.403 new 4-06-2002 13:21 Pagina 29