G
Operation
3 minutes after connecting the battery the detector is ready to start. If a
movement is detected, it starts the alarm. To reduce the battery current
demand, the alarm is followed by a pause of two minutes.
Note: In a quiescent condition the LED is always off. It switches on only if an
alarm is detected or during the test.
Test
In order to carry out the walk test it is necessary to select the test function
on the detector, pressing the push button test located in the lower part of the
plastic housing. The pause of two minutes after the detection will be exclu-
ded for two minutes and the LED on the detector will be enable.
A ”beep” indicates the passage of the detector to the test function. Adjust the
sensitivity of the detector to the minimum and in case of noisy environment
turn the “pulse-count” jumper to position 3 (the alarm starts after 3 steps
approximately).
Tampering alarm
At any moment by opening the enclosure, the tampering alarm starts.