Software Upload via FTP
This method uses FTP over the ethernet port and access to the Maintenance menu
either with either Telnet (over the ethernet port) or Kermit/HyperTeminal over the
serial port. Ensure that the network has been set up correctly (see "Setting the
INDeX IP Network Settings" on page 24).
This process allows for remote uploading of INDeX software whilst the INDeX is
running. Note however that the system must be restarted, which will stop all calls in
progress, to use the new software.
There are two methods available for uploading the software via FTP:
- preferred method is by using the
Administration
menu whilst the system is
running
- alternatively, if necessary, by using the Monitor Loader.
Using the Administration Menu
1. Access the switch and log on using either Telnet (see page 25) or the serial port
(see page 20).
2. From the
Administration
menu select
Maintenance
.
3. Start your command line FTP program.
a. In Windows 95, 98 and NT, select
Start | Run
and enter
ftp
.
b. Enter
open
n
where
n
is the IP address of the INDeX.
c. When requested enter your username.
d. When requested enter your password.
e. Enter
bin
to ensure that FTP file transfers use binary mode.
f. Enter
hash
if you want a visual indication of the transfer of data packets.
g. Enter
send
fn
PA
where
fn
is the file path of the software file to send.
h. Enter
close
to end the FTP connection.
i. With Windows FTP, enter
quit
to close the FTP window.
4. Return to the
Maintenance
menu. The
Release upload buffer
option should
display
PA Software Upload
. Whilst this message is displayed the system is
uploading the flash memory.
5.
Wait for this message to disappear before proceeding.
6. From the
Administration
menu, select
Channel Information
and select
System Shutdown.
7. When shut down, from the
Maintenance
menu, select
System Restart
and
press
N
8. "
Cold System Restart"
appears. Press
Y
and wait for the
"System Restart"
message (which will show the time and date of the restart).
9. Press
↵
and log on again.
10. You can now program the new INDeX software features.