Test code
Test description
Failure code
failure or another type of error resulting in no
display on the monitor.
Non critical operating system and switch diagnostic codes
If a noncritical operating and switch diagnostic test fails, the HEX display stops at the failed
test. The remaining diagnostics are not performed. The start sequence continues, but server
functionality can be compromised.
The following table shows the noncritical operating system and switch diagnostic codes with
the corresponding failure codes.
Note:
While the test is in progress, the following codes may appear for a short period. If these
messages display temporarily (that is, no longer than 1 second), a problem does not exist.
Status code
Operation description
Failure code
HOST
Continuation of BIOS diagnostics.
The monitor displays the BIOS start screen.
If a noncritical error occurs, the server
continues the start sequence.
P:XX
NT
The operating system start sequence
started.
Note:
If the CallPilot server software is not
installed, the HEX display remains at NT.
(This can occur if you are rebuilding a
system.) During CallPilot software
installation, the 8051 device driver is
copied to the operating system, at which
point the HEX display shows CDLN.
P:XX
Note:
For a description, see
on
page 27.
CDLN
8051 device driver on the operating system
has started; beginning of Cardlan interface
communication (DS30x interface
initialization)
The system controller communicates with
the switch, indicating that two cards are
installed, and waits for switch
acknowledgement.
CDLN
Neither DS30x interface
was initialized (both
failed).
C:01
Initialization of the first DS30x interface
C:01
Initialization of the first
DS30x interface failed.
Troubleshooting your Avaya CallPilot
®
system
26 Avaya CallPilot 202i Server Maintenance and Diagnostics
December 2010