8
Short press access standard Keypad functions. The numbered keys (1 to 0) are used for
Arming/Disarming (ON/OFF), Zone Shunt (Bypass), and other operation and programming
functions.
Short beep confirms each key press.
A short press on the AV-701 keypad key accesses the following special functions:
5
Chime
Instant Arming. Press key ‘5’ (requires programming at 071
-2) to Arm.
0
Shunt
Zone Bypass, by pressing key ‘0,’ followed by entering the Zone number.
0
Shunt
Zone Bypass via Code (requires programming, see address 071-5).
Press key ‘0’, while 4 LEDs are blinking, enter valid user code; When only 2 left
-
most LEDs are blinking, enter zone number(s) to be bypassed, 4 LEDs stop blinking,
‘Shunt’ LED remains on to confirm zone bypass, within 20 seconds enter your user
code to Arm the system.
0
Shunt
then
0
Shunt
AV-2004:
Group Bypass, by two presses on key ‘0.’ Group
-Bypass is
operative only if System is armed within 20 seconds after entry of this feature. Yellow LED will
flash and ‘h’ (Home) will be displayed for 1 second in confirmation.
AV-2048 Arming with Group Bypass: 2
nd
Group Bypass added, (address 034) and the procedure
enhanced; after selecting the Group Bypass, system is armed (without code entry). To bypass 1
st
group: Press “0” and
hold-down
“1”, to bypass 2
nd
group press ”0” and
hold-down
“2”, to
bypass
both groups press “0” and
hold-down
“0”. Yellow LED will flash; ‘h’ (Home) will be displayed
for 1 second in confirmation, then the Armed LED lights-up in confirmation.
When Group Bypass is selected the Shunt LED stops blinking eight seconds after arming. This
will prevent the LED light from disturbing sleepers near the keypad.
B. There is no exit/entry delay-warning buzzer at the keypad.
C. There are no ‘beeps’ at the keypad until an alarm occurs or Group Bypass is canceled.
D. When the keypad LEDs are turned off after Arming (requires programming), touching the
keypad will turn them on for 5 seconds.
For Group Bypass with code
(requires programming); Press key ‘0’, while four LEDs are blinking,
enter valid user code. When only 2 left-most LEDs are
blinking, press again ‘0’ key, ‘h’ will be
displayed and, 4 LEDs stop blinking. ‘Shunt’ LED is blinking to confirm Group Bypass, enter
your user code to Arm system within 20 seconds (otherwise Group Bypass will be removed).