XX - Event number (from 01 to 36), then HH_MM (Hour and Minutes) Event Time, Event (alarm
or opening/closing). More events are reported in the PC up and download log events.
Translate the display as following:
‘u’ (user number 1 to 8)
‘o’ or ‘c’
- opening or closing
Zone causing alarm-Will blink twice
tX - Tamper alarm form zone causing alarm (X)
H - Means Panic Alarm
Note: 3 lines (
) indicates power fail. In history events AC fail is displayed.
For example:
01 2 2 _ 2 4 u 1 o 02 2 3 _ 0 5 7 7 03 2 3 _ 3 5 H H 04 0 0 _ 0 8 u 1 c -
- Sign then long beep
Event 01
Time
User 1
Opening
Event 2 Time Alarm Zone 7 Event 3 Time Alarm Zone H Event 4 Time User 1 Closing
Display
indicates end of History
Zone no. blinks twice
During zone number display, keypad display blinks twice to indicate the zone number.
Browsing through Events History
Keys used for browsing:
2
Shunt
Display
Skip forward to next event
5
Chime
Display again current event
8
Program
Skip backward to previous event
9
Reset
Cancel History Event Mode and exit
When last event is displayed and attempting to move forward (key 2) a blank sign ‘–‘ is displayed
and a long warning beep indicating that it is the last event. Press key 8 to move backward, if no
key is pressed Event History stops and system returns to Use mode.
When starting History Events mode the events are displayed from starting to the end without any
break, until any browsing key had been pressed.
During History Event browsing, system will respond only to alarm or panic, Arming denied.
Alarm or Panic during History Event mode will quit this mode and system will set to Use
Mode (normal operation mode. Clearer History events are available when using the
download.
3.
0
Shunt
and
3
Status
Concise History of Tampered Zones:
Hold down key ‘0’ and then
hold down key ‘3’ to display the Tampered zone alarm s
equence.
New alarm will create a new history in place of old history.
4.
0
Shunt
and
1
Siren
Display and Setting of System Time:
Hold down key ‘0’ and then
hold-
down key ‘1’, three LEDs are blinking, wait fo
r the display of system time in 4-digit format.
To set new time, hold down key ‘0’ and then hold down key ‘1.’ Do not wait for time display;
enter the new time in 24-hour format.